A3
A3
+10V reference output
Voltage tolerance
±
3%
Nominal output current
5mA
Protection
Tolerates continuous short-circuit to 0V
A4
A4
A5
A5
Volt-free relay contact
Function
Drive status
Contact rating
2A resistive at 250V
AC
or 24V
DC
Contact resistance
100m
Ω
maximum
Update time
32ms (30Hz)
Open-contact withstand voltage
750V
AC
Voltage isolation from all other circuits in
the Drive
2.5kV
AC
(meets IEC664-1 with over-voltage category III)
Operation of the contact
Closed
AC
supply is applied to the Drive and the Drive is ready to
run (not tripped)
Open
AC
supply removed from the Drive, or
AC
supply is applied
to the Drive and the Drive has tripped
Warning
The relay must not be connected to an
AC
supply of over-
voltage category greater than II, as defined in IEC664-1
Insulation co-ordination for equipment within low voltage
systems
, section 2.2.2.1.1.
B1
B1
0V common