Logic table for the security system
The two levels of security are logically related, as follows:
Standard
security
User
security
Conditions
Parameters
that can be
read
Parameters
that can be
edited
Locked
Not set up
Each time the
AC
supply is
connected, or the user enters
800
in parameter
0.00
Menu 0
Menu 0
Unlocked
Not set up
The user enters the number
149
in parameter
0.00
All
All
Locked
Locked
Each time the
AC
supply is
connected (subsequent to user-
security being set up), or the
user enters
800
in parameter
0.00
Menu 0
None
Locked
Unlocked
The user enters the user-security
number in parameter
0.00
Menu 0
Menu 0
Unlocked
Locked
Each time the
AC
supply is
connected (subsequent to user-
security being set up), or the
user enters
149
in parameter
0.00
All
None
Unlocked
Unlocked
The user enters separately the
numbers for the user-
security code and standard-
security code in parameter
0.00
All
All
In all cases, parameter
0.00
can be accessed. See
Security procedures
later in
this chapter.