Dinverter
A
User Guide
Issue code: d2au9
67
Figure 5–12 Selecting a different menu
Changing the initial parameter to be displayed
At the time the
AC
supply is connected to the Drive, parameter
0.10
Motor
frequency
is automatically pre-selected as the initial parameter to be
displayed. This results in the following:
1
When
is pressed to enter Parameter, the pre-selected parameter
0.10
is displayed.
2
When the Drive is subsequently running, the display shows the value of
0.10
.
3
If other parameters are selected by a user for display or editing, the
value of the last parameter selected will be displayed when the Drive is
next running.
4
To select a different parameter to be displayed initially, enter the
required
menu.parameter
number in parameter
0.38
initial parameter
displayed selector
(eg. to display
0.12
Post-ramp speed reference
, enter
0.12
). Only Menu 0 parameter numbers can be selected.
Restoring all parameters to the
default values
Default values can be restored only when the Drive is not running. See
Chapter 7
Menu 0 parameters
for the default values.`
1
Set parameter
.00
as follows:
533
for a Drive operating on 50Hz
AC
supply frequency
544
for a Drive operating on 60Hz
AC
supply frequency
2
Momentarily press
to reset the Drive. The default values now
take effect.
Saving the default values
If new parameter-values had previously been saved, these (not the default)
values will apply when the
AC
supply is next connected to the Drive. If the
default values are required instead, they must be saved in the same way as
new values. Refer to
Saving the new value of a parameter
earlier in this
chapter to save the default values.