7.10.2 Setting Weigh Bin Batch weight
Materials with a lower bulk densities (ca. <35 lb/cu ft) may not fit in the weigh bin
and granulate may overflow. The batch weight must be reduced in this case. The
factory setting is 900 g for the TB100 model or 400 g for the TB045 model, (see
chart below).
Model
Batch Weight
Min Weight
Maximum Weight
TB045
400 g
280 g
480 g
TB100
900 g
630 g
1100 g
TB250
2500 g
1750 g
3000 g
TB500
4000 g
2800 g
5000 g
TB900
8100 g
5700 g
9800 g
TB1800
1800 g
12600 g
21600 g
TB2500
25000 g
17500 g
30000 g
TB3500
35000 g
24500 g
42000 g
Î
Press the input field beside "Batch
Weight and input the desired batch
weight with the keypad.
Î
Confirm the value with .
If the minimum value is not reached, the
minimum value from the chart is automati-
cally input. If the maximum value is ex-
ceeded, the maximum allowable value is
automatically input.
The batch weight can also be increased for
heavy bulk materials. This will make the
material throughput in lbs/hr somewhat
higher.
Î
Make sure that the weigh bin does not
overflow.
Summary of Contents for TrueBlend TB500-4
Page 2: ......
Page 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Page 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Page 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Page 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Page 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...