![Conair TrueBlend TB500-4 User Manual Download Page 105](http://html1.mh-extra.com/html/conair/trueblend-tb500-4/trueblend-tb500-4_user-manual_2649034105.webp)
TrueBlend
™
Operation
Edition: February 2007
103
7.19.5 Settings
Settings
Î
In the loader “status” and “setup”
screens press
to open the settings
screen to configure the hopper loaders
and conveying.
Setting type of hopper loader
Î
Press "Hopper Loader" on the "Settings"
screen.
Î
Input the name and type volume in cubic
feet of hopper loader.
The appropriate loading and discharge times
are preset depending on the type selection.
(They can be changed at any time).
Type
loading
discharge
(volume)
time [s]
time [s]
0.15
4
5
0.50
10
10
1.00
15
10
1.80
20
10
3.00
30
15
Sharing Conveying Pumps
If you are using only one blender and one pump, the default settings for the
wait list (WCN and LCO) should be adequate.
The Trueblend blender also has the ability to share conveying blowers between
blenders. This enables you to have one conveying blower that services multiple
blenders. This function requires that the blenders be networked together in an
ethernet network. If only two blenders are networked together, the blenders
may be connected directly together with a “crossover” style ethernet cable run
between the two receptacles located on the bottom of the control enclosure. If
more than two blenders are to be tied together, the blenders should be
Summary of Contents for TrueBlend TB500-4
Page 2: ......
Page 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Page 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Page 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Page 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Page 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...