TrueBlend
™
Operation
Edition: February 2007
71
7.9.3 Input Alarm mode
Every material component can be assigned
a specific alarm mode. The alarm mode
shows the alarm response to overmetering
or undermetering. The "Warn" mode is set
for regrind and “stop” for natural and addi-
tives at the factory:
Î
Press the down arrow for the selection
box and select the desired alarm mode.
•
------:
No alarm message, unit continues
to run without message.
•
Warn.:
Alarm message is displayed, but
unit continues to run.
•
Stop:
Alarm message is displayed, unit
is stopped.
7.9.4 Input Dosing retries
The “Dos. retry” specifies how often mate-
rial dispensing will be retried in the event of
undermetering before an alarm is displayed
(if alarm mode is set to "Warn" or "Stop",
see 7.9.3 Input Alarm mode).
The factory setting is 4.
(i.e. material will attempt four times to ob-
tain target weight. If it fails an alarm will
occur).
Î
Input the value for metering attempts
with the numeric keypad.
Î
Confirm the value with .