![Conair TrueBlend TB500-4 User Manual Download Page 30](http://html1.mh-extra.com/html/conair/trueblend-tb500-4/trueblend-tb500-4_user-manual_2649034030.webp)
SPECIFICATION NOTES
*
Maximum throughput rates are based on 35 lb/ft
3
pelletized material and using all standard valve sizes.
Use of reducer inserts will lower the rate shown.
The optional flow control valve will mount inside the
chassis in the space of the manual slide valve. Conair
recommends using the optional flow control valve
when mounting the blender on a stand, surge bin or
hopper.
Specifications may change without notice, consult with a
Conair representative for the most current information.
Ø6
{Ø152.4}
30 {762.0}
27 {685.8}
15 {381.0}
30 {762.0}
27 {685.8}
15 {381.0}
8 {203.2}
15 {381.0}
24 {609.6}
8 {203.2}
15 {381.0}
16 {406.4}
MOUNTING INTERFACE
Dimensions
shown in inches
and {mm}.
Top view
Front view
Side view
Control
B
C
F
E
D
6
5
4
5
MODELS
TB1800-4
TB1800-5
TB1800-6
Performance characteristics
Batch size lbs {g} (grams or kilograms)
40 {18000}
40 {18000}
40 {18000}
Maximum throughput lbs/hr
{kg/hr}
*
6000 {2722}
5500 {2495}
4800 {2177}
Bin capacity - main ingredient
ft
3
{liter}
6 {170}
6 {170}
6 {170}
Bin capacity - minor ingredient
ft
3
{liter}
6 {170}
4 {113}
4 {113}
Maximum number of materials
4
5
6
Number of major valves
4 (5X5)
3 (5X5)
2 (5X5)
Number of minor valves
0
2 (2X5)
4 (2X5)
Dimensions
inches {mm}
A - Height above mounting plate
94.4 {2397.8}
94.4 {2397.8}
94.4 {2397.8}
B - Width
53.0 {1346.2}
53.0 {1346.2}
53.0 {1346.2}
C - Depth
53.0 {1346.2}
53.0 {1346.2}
53.0 {1346.2}
D - Controller height
8.25 {209.6}
8.25 {209.6}
8.25 {209.6}
E - Controller width
9.25 {235.0}
9.25 {235.0}
9.25 {235.0}
F - Controller depth
4.75 {120.6}
4.75 {120.6}
4.75 {120.6}
Weight
lbs {kg}
Installed
1465 {665}
1498 {679}
1532 {695}
Shipping
1715 {778}
1748 {793}
1782 {808}
Voltage
total amps
220V/1 phase/50 hz
11.3
11.3
11.3
220V/1 phase/60 hz
11.3
11.3
11.3
240V/3 phase/60 hz
7.5
7.5
7.5
400V/3 phase/50 hz
5.0
5.0
5.0
480V/3
phase/60 hz
4.5
4.5
4.5
575V/3 phase/60 hz
3.9
3.9
3.9
Compressed air requirements
0.3 ft
3
/min @ 90 psi {6 bars @ 0.14 liters/sec}
3/8 in. NPT fitting
Maximum loader sizes
4 DL25
3 DL25
2 DL15
2 DL25
4 DL15
2 DL25
2 DL15
3 DL25
2 AR10
2 DL25
4 AR10
2 DL25
2 AR10
4 DL20
2 DL15
4 DL20
4 DL20 2 AR10
A
5 position
4 position
6 position
1
2
1
4
2
4
3
1
3
5
2
3
4
5
6
front
front
front
NOTE:
Side and front view drawings are shown for model TB1800-6.
The bin positions change for a TB1800-4 and TB1800-5 models, see
the top view.
T r u e Bl e nd™ T B
1800
- 4
T e c h n i c a l S p e c i f i c a t i o n s
TB1800-5,
and
T B
1800
- 6
2
8
Edition:
February
200
7
Summary of Contents for TrueBlend TB500-4
Page 2: ......
Page 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Page 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Page 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Page 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Page 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...