If too much or too little was metered in a batch, this is compensated accordingly
The metering process is self-optimizing on the next batch.
The regrind is metered first and deducted from the total batch weight. If there is
more than one virgin material, the percentages are interpreted as ratios of the vir-
gin materials and dispensed next.
If there are multiple additive naturals or additive batches, they are metered in or-
der of ascending percentage of the total regardless of the sequence of the supply
hoppers.
7.9 Component
setup
The material component values for a batch are entered as percentages.
Conditions
The "TrueBlend Status" and
"TrueBlend Totals" screens show the vari-
ous material hoppers with the factory mate-
rial assignment. The material types in the
material hoppers can also be changed. The
outer number in the hoppers shows the set
value for the batch in % (TrueBlend Status)
or the total weight in kg (TrueBlend Totals).
Î
Press the relevant supply hopper to
open the "Setup Component" screen.
Î
Make the following settings for all com-
ponents.
Summary of Contents for TrueBlend TB500-4
Page 2: ......
Page 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Page 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Page 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Page 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Page 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...