Appendix
TrueBlend
™
144
Edition: February 2007
9
Route item 6 between 5 and 7 and insert.
10
Re-install sensor and wiring. Adjust flow through item 2 so a small amount
of air is bleeding from the opening in item 1. Adjust the insertion level and
direction of item 1 so the air is blowing across the face of the sensor.
Insertion depth into the chamber should be minimal as possible so tube
does not contact mixer blade - tighten item 8 on item 1. The air should be
adjusted so fines are cleaned from the sensor but the airflow should not
blow material completely away which may cause a false empty situation.