CDM-Qx Satellite Modem
Revision
6
Remote Control
MN/CDMQx.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Faults and Status
N/A
12 bytes
Query only
Unit returns the current
highest-prority
fault and status codes for the Unit (hardware),
TX Traffic, RX Traffic, and ODU in the form abcdef, where:
a=Unit Faults:
0=No Faults
1=Power Supply Fault, +5 volts
2=Power Supply Fault, +12 volts
3=Power Supply Fault, -5 volts
4=Power Supply Fault, +23 volts
5=Power Supply Fault, -12 volts
9=Ref PLL Lock
F=EEPROM Checksum error
6,7,8,A,B,C,D,E are reserved for future expansion
bb
=fault codes for slot#1 can be Tx or Rx Traffic status
cc
=fault codes for slot#2 can be Tx or Rx Traffic status
dd
=fault codes for slot#3 can be Tx or Rx Traffic status
ee
=fault codes for slot#4 can be Tx or Rx Traffic status
TX Traffic status:
00=TX Traffic OK
01=No Clock from Terrestrial Interface
03=TX FIFO Slip
06=TX Synthesizer Lock
07=AUPC Upper Limit Reached
09=AIS Detected on Incoming Data
0B=Bipolar violation on G.703 Interface
0F=TX EEPROM Checksum Error
12=Power supply fault, +5 volts
13=Power supply fault, -5 volts
14=Power supply fault, +12 volts
15=Power supply fault, -12 volts
16=Power supply fault, +23 volts
the rests are reserved for future expansion
RX Traffic status:
0=RX Traffic OK
1=Demodulator Unlocked
3=AGC Alarm – signal out of range
5=RS Frame SYNC alarm
7=EDMAC Frame SYNC alarm
8=RX 1
st
LO Synthesizer Lock
9=RX 2
nd
LO Synthesizer Lock
A=Buffer Under
B=Buffer Overflow
D=Eb/No alarm
E=AIS detected on incoming data
F=RX EEPROM checksum error
10=Demod FPGA not programmed
11=Turbo FPGA not programmed
12=Power supply fault, +5 volts
13=Power supply fault, -5 volts
14=Power supply fault, +12 volts
15=Power supply fault, -12 volts
16=Power supply fault, +23 volts
17=QDI Deframer Unlocked
18=Buffer Clock Activity
the rests are reserved for future expansion
f=ODU status: (for L-Band unit only)
0=No ODU Faults
1=BUC PLL
3=BUC Current
5=BUC Voltage
7=LNB Current, 9=LNB Voltage, B=BUC Temperature, D=BUC Checksum
N/A FLT?
FLT=abbccddeefgh
(see description of
arguments)
g=Change in fault
status since last poll.
h=Change in unit
configuration since
last poll
(see description of
arguments)
C-27
Summary of Contents for CDM-Qx
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Page 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Page 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...