CDM-Qx Satellite Modem
Revision
6
Remote Control
MN/CDMQx.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Group
GRP
1 byte
Command or Query
Group a modulator/demodulator pair into a modem
A grouped mod and demod will respond to either address
0=Both sides ungrouped
1=Left side (as viewed from back of chassis) grouped
2=Right side grouped
3=Both sides grouped
Example: GRP=3 (both sides of chassis are grouped into modems)
GRP=
GRP?
GRP*
GRP#
GRP$
GRP^
GRP? GRP=x
T1 Line
Build-Out
LBO=
1 byte, value of
0 though 4
Command or Query.
Valid only for T1 interface, where:
0=0 to 133 feet
1=133 to 266 feet
2=266 to 399 feet
3=399 to 533 feet
4=533 to 655 feet
Example: LBO=2
LBO=
LBO?
LBO*
LBO#
LBO$
LBO^
LBO@
LBO? LBO=x
(see description
arguments)
IP Address
IPA=
18 bytes
numerical
Command or Query
Used to set the IP Address and network prefix for the 10/100
BadeTX Ethernet management port, in the format:
xxx.xxx.xxx.xxx.yy where:
yy is the network prefix (0 to 31)
Example: 010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA? IPA=xxx.xxx.xxx.xxx
.yy
(see description of
arguments)
Request to Send
RTS=
1 byte, value of
0, 1, 2
Command or Query
Defines how RTS/CTS will operate at the main data interface
0=RTS/CTS Loop, No Action
RTS and CTS are looped, so that CTS echoes the state of RTS,
but RTS does not control the ON/OFF state of carrier.
1=Loop, RTS Controls TX O/P
RTS and CTS are looped, so that CTS echoes the state of RTS
and RTS controls the ON/OFF state of carrier (in order words,
the modem will not bring up its TX carrier until RTS is asserted.
2=Ignore RTS, Assert CTS
Example: RTS=0 (RTS/CTS Loop, No Action)
RTS=
RTS?
RTS*
RTS#
RTS^
RTS? RTS=x
(see description of
arguments)
HSSI handshake
control (valid only
for HSSI
interface)
HHC=
1 byte, value of
0,1
Command or Query.
Defines how TA/CA control the HSSI interface.
0 = TA to CA loop (default)
1 = RR control CA, TA control Tx output.
Example: HHC=0 (TA to CA loop)
HHC=
HHC?
HHC*
HHC#
HHC^
HHC? HHC=x
(see description of
arguments)
C-19
Summary of Contents for CDM-Qx
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Page 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Page 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Page 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Page 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Page 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...