CDM-Qx Satellite Modem
Revision
6
Remote Control
MN/CDMQx.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
RX Frequency Offset
N/A
6 bytes
Query Only
Unit returns the value of the measured frequency offset of the
carrier being demodulated, in the form sxxx.x, where:
xxx.x=value (range from 0 to 200 kHz, 100 Hz resolution)
R999.9 if the demodulator is unlocked
Example: RFO=+002.3 (2.3 kHz)
N/A RFO?
RFO=sxxx.x
(see description of
arguments)
Buffer Fill State
N/A
2 bytes
Query only
Unit returns the value of the buffer fill state, between 1 to 99%
Returns 00 if demodulator is unlocked
Example: BFS=33 (33%)
N/A BFS?
BFS=xx
(see description of
arguments)
Temperature of
Modulator
N/A
3 bytes
Query only
It returns the value of the internal card temperature, in the form of
sxx (degrees C)
s=sign (+ or – character)
xx=value
Example: TMP=+26
N/A TMP?
TMP=sxx
(see description of
arguments)
Temperature of the
Base Unit
N/A
3 bytes
Query only
Unit returns the value of the internal base unit temperature, in the
form of sxx (degrees C)
s=sign (+ or – character)
xx=value
Example: ITP=+26
N/A ITP?
ITP=sxx
(see description of
arguments)
C-33
Summary of Contents for CDM-Qx
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Page 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Page 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Page 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Page 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Page 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...