CDM-Qx Satellite Modem
Revision 6
EDMAC Channel
MN/CDMQx.IOM
7.3
Setup Summary
To access a distant-end unit:
•
Designate a Master/Slave pair: Master at the local-end, Slave at the distant-end.
•
On the local-end unit: Enable framing and EDMAC, define the unit as MASTER,
then enter the bus address. This is constrained to be ‘base 10' meaning that only
addresses such as 10, 20, 30, 40 etc, are allowed.
•
Choose a unique bus address for the distant-end. This should normally be set to
the ‘base 10' a 1. For example, if the MASTER unit is set to 30, choose
31 for the distant-end unit.
•
On the distant-end unit: Enable framing and EDMAC, define the unit as SLAVE,
then enter the bus address. The orange EDMAC Mode LED should be
illuminated.
•
Set the local-end unit to RS485 remote control, and set the bus address of this
local unit. The orange Remote Mode LED should be illuminated.
•
Once the satellite link has been established, connect the M&C Computer, and
begin communications, with both the local and distant end units.
NOTE:
EDMAC modes are fully compatible with AUPC modes.
7–3
Summary of Contents for CDM-Qx
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Page 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Page 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Page 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Page 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Page 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...