CDM-800 Gateway Router
Revision 1
Serial-based Remote Product Management
MN-CDM800
6–6
6.2.2.5 Instruction Code Qualifier
This
is
a
single
character
that
further
qualifies
the
preceding
instruction
code.
Code
Qualifiers
obey
the
following
rules:
From
Controller
‐
to
‐
Target
,
the
only
permitted
characters
are:
Character
Definition
=
(ASCII code 61)
This character is used as the Assignment Operator (AO). It establishes that the Instruction Code that precedes it is to
be used as a command to assign or configure operation. The instruction set that follows serves to assign the Target’s
new parameter setting or operational value.
Example: In a message from Controller-to-Target, IG1=aaa.bbb.ccc.ddd/yy means “set the GE Port IP address to
aaa.bbb.ccc.ddd/yy”
?
(ASCII code 63)
This character is used as the Query Operator (QO). It establishes that the Instruction Code that precedes it is to be used
as a query that returns the Target’s current configured parameter setting or operational value.
Example: From Controller-to-Target, IG1? means “what’s the current GE Port IP address?”
From
Target
‐
to
‐
Controller
,
the
only
permitted
characters
are:
Character
Definition
=
(ASCII code 61)
This character is used in two ways:
a.
If the Controller sends a query to the Target – for example, CMD? (meaning “what’s current value of this parameter?”)
– the Target responds with CMD=xxx, the value for that queried parameter.
b.
If the Controller sends an instruction to set a parameter to a particular value, and the value sent is valid, the Target
acknowledges the message and responds with CMD= (with no message arguments).
?
(ASCII code 63)
If the Controller sends an instruction to set a parameter to a particular value, and the value sent is not valid, the Target then
acknowledges the message and responds with, for example, CMD? (with no message arguments). This indicates that there
was an error in the message sent by the Controller.
Summary of Contents for CDM-800
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 20: ...CDM 800 Gateway Router Revision 1 Preface MN CDM800 xviii Notes...
Page 30: ...CDM 800 Gateway Router Revision 1 Introduction MN CDM800 1 10 Notes...
Page 36: ...CDM 800 Gateway Router Revision 1 Installation MN CDM800 2 6 Notes...
Page 120: ...CDM 800 Gateway Router Revision 1 Serial based Remote Product Management MN CDM800 6 12 Notes...
Page 130: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...