CDM-800 Gateway Router
Revision 1
Rear Panel Connections
MN-CDM800
3–14
3.3.3.2 DC Operation – Replacing Fuses
DISCONNECT
THE
POWER
SUPPLY
BEFORE
PROCEEDING!
The
fuses
are
contained
within
individual
screw
‐
in
receptacles
located
below
the
terminal
blocks
(
Figure
3
‐
10
).
Figure 3-10. Replacing CDM-800 DC Fuses
To
replace
the
fuses:
•
First,
unscrew
either
fuse
holder
from
its
receptacle.
Then,
remove
and
replace
the
fuse:
o
Use
T3A
(3
Amp)
fuses
for
standard
operation
o
Use
T5A
(5
Amp)
fuses
when
a
Block
Upconverter
(BUC)
is
installed.
•
Screw
either
fuse
holder
back
into
its
receptacle.