CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Ethernet-based Remote Product Management
MN-CDM750
6–4
6.3.3 SNMP Traps
The
modem
has
the
ability
to
send
out
SNMP
traps
when
certain
events
occur
in
the
modem.
The
modem
sends
out
traps
when
an
alarm
or
a
fault
occurs
in
the
modem.
These
include
unit
faults,
Tx
faults,
Rx
faults,
and
ODU
faults.
A
trap
is
sent
both
when
a
fault
occurs
and
is
cleared.
The
modem
supports
both
SNMPv1
traps
and
SNMPv2
notifications.
Which
style
of
traps
the
modem
sends
can
be
configured
by
the
user
using
the
CDM750SNMPTrapVersion
OID:
•
The
CDM
‐
750
supports
the
following
MIB2
SNMPv1traps
/
SNMPv2
notifications:
MIB2 SNMPv1 trap: Authentication Failure
5
MIB2 SNMPv2 notifications: Authentication Failure
1.3.6.1.6.3.1.1.5.5
•
The
CDM
‐
750
supports
the
following
Alarms
and
Faults
SNMPv1
traps:
cdm750UnitAlarmV1
6247600
cdm750TxTrafficAlarmV1
6247601
cdm750RxTrafficAlarmV1
6247602
cdm750TrapStoredEventAlarm
6247603
cdm750RedundancySwitch
6247604
•
The
CDM
‐
750
supports
the
following
Alarms
and
Faults
SNMPv2
notifications:
cdm750UnitAlarm
1.3.6.1.4.1.6247.55.2.1.1.1
cdm750TxTrafficAlarm
1.3.6.1.4.1.6247.55.2.1.1.2
cdm750RxTrafficAlarm
1.3.6.1.4.1.6247.55.2.1.1.3
cdm750TrapStoredEventAlarm
1.3.6.1.4.1.6247.55.2.1.1.4
cdm750RedundancySwitch
1.3.6.1.4.1.6247.55.2.1.1.5
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...