CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Front Panel Operation
MN-CDM750
5–47
Otherwise:
Rx-Params: EsNo=>23.5 dB
⌂
F=+005.0 kHz
MODCOD: QPSK ½ RxLevel= -31dBM
Note
the
following:
Item
Description
Es/No
The value of the Es/No calculated by the demodulator. Es/No is the energy per Symbol received
(Es) divided by the noise spectral density (No). Note that the Es/No reading assumes that a linear,
non-distorted carrier is being received. If a carrier is operating at or near saturation and there are
nonlinear distortions, the Es/No reading may be inaccurate, especially when demodulating 16APSk
and 32APSK carriers.
Δ
F
The frequency offset of the received carrier, in kHz, with a displayed resolution of 100 Hz.
Rx-Level
A dBm reading indicating the signal level of the desired receive carrier. Resolution: 0.5dB.
ModCod
The current ModCod.
5.2.4.5 Monitor: CnC (Carrier-in-Carrier Parameters)
CnC-Params: Freq-offset=-123.4kHz
Ratio:+1dB Delay=230.4ms
When
enabled
and
locked,
this
read
‐
only
screen
displays
the
CnC
performance
data.
Note
the
following:
•
The
Monitor:
CnC
screen
refreshes
once
every
second.
•
CnC
parameters
need
to
be
within
the
tolerances
specified
in
Sect.
1.4.8
DoubleTalk
TM
Carrier
‐
in
‐
Carrier
®
(CnC)
.
•
Ideal
operation
occurs
when
the
CnC
Ratio
is
0
db.
Ratios
that
are
higher
or
lower
–
approaching
±7
dB
–
will
cause
degradation.
Ratios
beyond
±7
dB
may
cause
complete
unlock
of
circuit.
•
The
Delay
in
a
properly
working
CnC
link
is
typically
between
230
ms
and
290
ms.
Delay
when
bench
‐
testing
CnC
operation
is
typically
less
than
100
µs.
5.2.4.6 Monitor: Stats (Statistics)
IP BasebandFraming Compression
34
Use
the
W
X
arrow
keys
to
select
IP,
BasebandFraming
,
or
Compression
,
and
then
press
ENTER
.
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...