CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Front Panel Operation
MN-CDM750
5–16
Item
Description
TxPLL
(Alarm) The
Tx Clock PLL
is railed high or low indicating that the Tx Clock Source is
substantially different than the rate of the Tx data.
InpSigLoss
(Alarm)
Input Signal Loss
indicates that no traffic is being seen by the OC3/STM-1 interface
on the TX-IN connector.
RxPLL
(Alarm) The
Rx Clock PLL
is railed high or low indicating that the Rx Clock Source is
substantially different than the rate of incoming data.
RxOF
(Alarm)
Rx Overflow
indicates that the traffic received by the demod is exceeding the clock
RxClock setting and is therefore overflowing the buffer causing the buffer to re-center and
take a data hit.
RxUF
(Alarm)
Rx Underflow
indicates that the traffic received by the demod is not keeping up with
the clock RxClock setting and is therefore underflowing the buffer causing the buffer to re-
center and take a data hit.
Using
TxPLL
as
the
example:
Tx Pll Mask: Masked
Alarm Fault Mask Fault-Tx On
The
top
line
notes
the
active
mask
selection.
On
the
bottom
line,
use
the
W
X
arrow
keys
to
select
Alarm
,
Fault
,
Mask
,
or
Fault
‐
Tx
On
for
the
TxPll
and
InpSigLoss
menus,
or
Alarm
,
Fault
,
or
Mask
for
the
RxPll
,
RxOF
and
RxUF
menus.
Press
ENTER
when
done.
Note
the
following:
Mask Type
Description
Redundancy Switchover and Tx Mute
Alarm
Alarms can be viewed from the
Monitor: Live
Alarms
menu (
Unit Status LED to turn AMBER.
An alarm WILL NOT cause a redundancy
switch and WILL NOT mute the Tx carrier
Fault
Faults can be viewed in the
Monitor: Stored-
Events log (Sect. 5.2.4.2)
.
Faults cause:
•
The Unit Status LED to turn RED
•
The J1 Alarm Connector to show a Fault
A fault WILL cause a redundancy switch
and WILL mute the Tx carrier
Mask
Masking the event has the effect of ignoring the
event – it can no longer be logged and is not
seen in any menu.
Mask WILL NOT cause a redundancy
switch and WILL NOT mute the Tx carrier
Fault-Tx On
Faults can be viewed in the
Monitor: Stored-
Events log (Sect. 5.2.4.2).
Faults cause:
•
The Unit Status LED to turn RED
•
The J1 Alarm Connector to show a Fault
A Fault-Tx On WILL cause a redundancy
switch and WILL NOT mute the Tx carrier
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...