CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Front Panel Operation
MN-CDM750
5–28
On
the
top
line:
The
active
Pilot
setting
displays
here.
On
the
bottom
line:
The
user
‐
programmed
Goldcode
displays
here.
Press
ENTER
or
CLEAR
to
return
to
the
previous
menu.
5.2.2.3.7 (CONFIG) Rx: EsNo
Receive EsNo Alarm Point = 02.0 dB
(
v
)
To
edit
the
EsNo
Alarm
Point:
First,
use
the
W
X
arrow
keys
to
select
a
digit
to
edit,
and
then
use
the
ST
arrows
keys
to
change
that
digit.
Note
the
following:
•
The
permitted
range
is
from
00.1
to
16.0
dB.
•
If
the
Rx
Es/No
falls
below
this
value
and
the
fault
is
NOT
masked,
a
receive
traffic
fault
will
be
generated.
Press
ENTER
when
done.