CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Appendix G
MN-CDM750
G–4
G.3.3 Status Items
Status
items
are
not
strictly
part
of
the
Statistics
but
are
important
items
used
for
monitoring
for
current
conditions.
G.3.4 BER Testing
Item
Comments
ModCod Selection
Allows selection of ModCod for test.
PN Sequence Test On/Off
Enable / Disable Test.
BER Test Result
Test results – continuous. PN data is generated in the Framer (Fig. B-1 Block 6) and recovered in
the Deframer (Fig. B-1 Block 5).
G.3.5 ACM Modulator Status
Item
Comments
Current TX ModCod
Currently active Tx ModCod.
Remote Es/No Reading
Es/No from distant end.
G.3.6 ACM Demodulator Status
Item
Comments
Rx ModCod
Currently active Rx ModCod.
Local Es/No Reading
Es/No of local demodulator.
G.3.7 CnC Status
Item
Comments
CnC PSD Ratio
Power Spectral Density (PSD) ratio at local end.
PSD = Interferer - Distant, density (dB).
CnC Ratio (Power)
Power Ratio at local end.
CnC Ratio = Interferer - Distant, power (dB).
CnC frequency offset
∆
F between Interferer and Distant carriers.
CnC Delay
Round trip delay of Tx carrier in ms (measured in Fig. B-1 Block 8).
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...