CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Serial-based Remote Product Management
MN-CDM750
7–37
7.5.11 Modem Performance Indication
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Rx Signal
Level
N/A
5 bytes
Query only.
Returns value of Rx signal level in the form xxxxx, where:
xxxxx = value, in dBm, between –20 and –90 dBm.
If >-20dBm, returns RSL=GT-20 (GT = ‘greater than’)
If <-90 dBm, returns RSL=LT-90 (LT = ‘less than’)
If <-20 and >-90 returns RSL=EQ-XX (EQ = ‘equal to’)
If in the range of –20 to –90dBm, returns RSL=YY-xx
Example: RSL=EQ-45 (indicating –45 dBm)
N/A
RSL?
RSL=xxxxx
(see description
of arguments)
Rx Frequency
Offset
N/A
6 bytes
Query only.
Returns value of measured frequency offset of the carrier being demodulated, in the form sxxx.x, where:
s = sign (+ or -)
xxx.x = value ranging from 0 to 200 kHz, in 100 Hz resolution.
Returns 999999 if the demodulator is unlocked.
Example: RFO=+002.3 (s 2.3 kHz)
N/A
RFO?
RFO=sxxx.x
(see description
of arguments)
Temperature
N/A
3 bytes
Query only.
Returns the highest of 4 temperature sensors. Value of the internal temperature sensor, in the form xxx, where:
xxx = degrees C
Example: TMP=+26
N/A
TMP?
TMP=xxx
(see Description of
Arguments)
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...