CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Front Panel Operation
MN-CDM750
5–12
(CONFIG: INTF) PIICX (G.703)
Æ
RxBuffer
Rx Buffer: BufferSize ReCenter
Fill Status = 00% (
)
Use
the
W
X
arrow
keys
to
select
BufferSize
or
ReCenter
,
and
then
press
ENTER
.
The
bottom
line
displays
the
present
RxBuffer
Fill
Status
as
a
percentage.
If
the
RxBuffer
Fill
Status
is
dropping
(approaching
0%),
this
indicates
that
the
Rx
traffic
is
not
keeping
up
with
the
Rx
Clock
setting
and
a
data
underflow
is
occurring.
If
the
RxBuffer
Fill
Status
is
increasing
(approaching
100%)
the
Rx
traffic
is
coming
in
faster
than
the
Rx
Clock
setting
accommodates,
and
a
data
overflow
is
occurring.
(CONFIG: INTF) PIICX (G.703)
Æ
RxBuffer
Æ
BufferSize
Rx Buffer Size: 02.0 ms
(
)
Use
the
ST
arrow
keys
to
increment/decrement
the
Rx
Buffer
Size
time
value
(from
2
ms
to
75
ms
in
0.5
ms
steps),
and
then
press
ENTER
.
(CONFIG: INTF) PIICX (G.703)
Æ
RxBuffer
Æ
Recenter
Rx Buffer: ReCenter
(
)
In
the
event
of
data
underflow
or
overflow
(as
indicated
by
the
Fill
Status
percentage
reported
on
the
RxBuffer
menu)
press
ENTER
to
ReCenter
the
Rx
Buffer
depth
to
50%.
(CONFIG: INTF) PIICX (G.703)
Æ
Mask
Masks: TxPll InpSigLoss ExtClkAct
RxPll RxOF RxUF ExtClkInRange
To
define
how
many
or
how
few
of
the
interface
alarm
or
fault
states
are
reported:
Use
the
W
X
arrow
keys
to
select
TxPll,
InpSigLoss,
ExtClkAct
,
RxPll
,
RxOF
,
RxUF
,
or
ExtClkInRange
,
and
then
press
ENTER
.
Note
the
following:
Item
Description
TxPLL
(Alarm) The
Tx Clock PLL
is railed high or low indicating that the Tx Clock Source is
substantially different than the rate of the Tx data.
InpSigLoss
(Alarm)
Input Signal Loss
indicates that no traffic is being seen by the G.703 interface on
the TX-IN connector.
ExtClkAct
(Alarm)
External Clock Activity
indicates that the External Clock is selected by either the
TxClock or RxClock but no clock is present on J8.
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...