11. Technical information
General points
P
ower supply NIMH rechargeable
battery (NIMH) (4,8 V ª 1200 mA/h)
C
hargers: The only chargers used for
recharging the battery bear the follo-
wing information:
Type TR503-02-E-133A03
Input 90-264 VAC / 47-63Hz / 0.5A max.
Output 9V / 400mA / 6W
Type TR1509-06-E-133A03
Input 90-264 VAC / 47-63Hz / 0.5A max.
Output 9V / 1.4A / 15W
Type TR503-02-A-133A03
Input 90-264 VAC /47-63Hz / 0.5A max.
Output 9V / 400mA / 6W
Type TR1509-06-A-133A03
Input 90-264 VAC / 47-63Hz / 0.5A max.
Output 9V / 1.4A / 15W
Type TR503-02-U-133A03
Input 90-264 VAC / 47-63Hz / 0.5A max.
Output 9V / 400mA / 6W
Type TR1509-06-U-133A03
Input 90-264 VAC / 47-63Hz / 0.5A max.
Output 9V / 1.4A / 15W
Neurostimulation
A
ll electrical specifications are given
for a charge between 500 and 1000
ohms per channel.
Channels: four independent and individually
adjustable channels electrically insulated from
each other and from ground
Impulse shape: constant rectangular current
compensated to eliminate any direct current
component to avoid any residual skin polarisation
Maximum current of an impulse: 100 milliamperes
Intensity increase interval:
– Manual stimulation intensity adjustment: 0-
694 (energy units)
– Impulse duration: 0.5 mA
From 50 to 400 microseconds
Maximum quantity of electricity per impulse: 80
microcoulombs (2 x 40 µC compensated)
Typical rise time for an impulse
3 microseconds (between 20% and 80% of
maximum current)
Impulse frequency
from 1 to 150 Hertz
8. Standards
T
he Compex is based directly on me-
dical technology.
T
o guarantee your safety, the design,
manufacturing and distribution of
Compex are in conformity with the
requirements of the European Direc-
tive 93/42/CEE.
T
he device is in conformity with the
standard for general safety rules for
electromedical devices IEC 60601-1,
the standard for electromagnetic
compatibility IEC 60601-1-2 and the
standard for special safety rules for
nerve and muscle stimulators IEC
60601-2-10.
C
urrent international standards (IEC
60601-2-10 AM1 2001) require that a
warning be given concerning the ap-
plication of electrodes to the thorax
(increased risk of cardiac fibrillation).
D
irective 2002/96/CEE Waste electri-
cal and electronic equipment
(WEEE).
9. Patent
S
nap electrode: patent pending.
10. Normalised symbols
I
mportant: Under some condi-
tions, the effective figure for the
stimulation pulses can exceed 10 mA
and 10 V. The information given in this
handbook must be strictly observed.
T
he Compex is a class II device
unit with its own internal electric
power, with type BF applied sections.
W
aste electrical and electronic
equipment (WEEE).
T
he “On/Off” switch is a multi-
function key:
Functions
Symbol N°(according to CEI 878)
On/Off (2 positions, stable)
01-03
Waiting or preparation
for part of the unit
01-06
Stop (switching off)
01-10
EUROPE
USA
UK
Manuel Full Fitness:Full Fitness 0706 5/02/08 10:10 Page 166
Summary of Contents for full fitness
Page 2: ...Manuel Full Fitness Full Fitness 0706 5 02 08 10 08 Page 2...
Page 316: ...Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 316...
Page 317: ...Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 317...
Page 318: ...Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 318...
Page 319: ...Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 319...
Page 320: ...320 Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 320...
Page 321: ...321 Manuel Full Fitness Full Fitness 0706 5 02 08 10 12 Page 321...