3-25
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Installing Hardware Options Comments:
File Name: E-ch3.doc Last Saved On: 4/23/97 11:22 AM
Removable Media Storage
A 1.44-MB diskette drive comes standard in removable media drive bay 1 and
a CD-ROM drive is installed in bay 4. Three half-height removable storage
devices such as diskette, tape, or hard drive can be installed in bays 2, 3,
and 4.
Drive Installation Guidelines
When adding SCSI hard drives to your ProLiant 800 server, pay attention to
the following guidelines:
A maximum of seven SCSI devices per controller may be added.
The SCSI ID for each device should be the same as the bay number
(Bay 0 = SCSI ID 0).
If only one SCSI hard drive is used, install it in bay 0.
Compaq SCSI cables for the ProLiant 800 server are terminated. Be
sure to remove all terminating jumpers from third-party SCSI devices.
Supported Compaq SCSI options are not terminated.
SCSI ID Settings for Compaq Hard Drives
The following chart provides the SCSI ID jumper settings for
Compaq SCSI hard drives.
Table 3-3
Drive Bay Numbers and Corresponding SCSI ID Settings
Drive Bay Number
SCSI ID
Bit 2
Bit 1
Bit 0
4
4
ON
OFF
OFF
3
3
OFF
ON
ON
2
2
OFF
ON
OFF
1
1
OFF
OFF
ON
0
0
OFF
OFF
OFF