Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
Loose cable detected -
logical drives may be
marked FAILED until
corrected
Controller unable to
communicate with one or
more physical drives,
probably because of a
cabling problem. Logical
drives may be in a FAILED
state until the condition is
corrected, preventing
access to data on the
controller.
Check all controller and drive cable
connections.
Mirror data miscompare
Data was found at
reinitialization in the
posted write memory,
however, the mirror data
compare test failed
resulting in data being
marked as invalid. Data
loss is possible.
Replace the array accelerator board.
Mirrored memory
location errors
Soft errors occurred when
attempting to read the
same data from both sides
of the mirrored memory.
Data loss will occur.
Replace the array accelerator board.
No configuration for
Accelerator Board
The array accelerator
board has not been
configured.
If the array accelerator board is present, run the
System Configuration Utility to configure the
board, if desired.
continued