8-41
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
Controller is located in
special “video” slot
Controller is installed in
slot for special video
control signals. If
controller is used in this
slot, LED indicators on
front panel may not
function properly.
Install the controller in a different slot and run
the System Configuration Utility to configure the
controller and nonvolatile RAM.
Controller is not
configured
Controller is not
configured. If controller
was previously configured
and you change drive
locations, there may be a
problem with placement of
the drives. DAAD examines
each physical drive and
looks for drives that have
been moved to a different
drive bay.
Look for messages indicating which drives have
been moved. If none appear and drive
swapping did not occur, run the System
Configuration Utility to configure the controller
and nonvolatile RAM. Do not run the System
Configuration Utility if you believe drive
swapping has occurred.
Controller needs
replacing (DAAD
Error 102)
IDA firmware is less than
version 0.96.
Replace the controller as soon as possible.
Controller needs
replacing (DAAD Error
104)
The Intelligent Array
Expansion System
firmware is less than
version 1.14.
Replace the controller as soon as possible.
continued