DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
Accelerator parity write
errors: n
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
If there are many parity errors, you may need
to replace the array accelerator board.
Accelerator status:
Permanently disabled
Array accelerator board has
been permanently disabled.
It will remain disabled until
it is reinitialized using the
System Configuration Utility.
Check the Disable Code field. Run the System
Configuration Utility to reinitialize the array
accelerator board.
Accelerator status:
Possible data loss in
cache
Possible data loss detected
during power-up due to all
batteries being below
sufficient voltage level and
no presence of the
identification signatures on
the array accelerator board.
There is no way to determine if dirty or bad
data was in the cache and is now lost.
Accelerator status:
Temporarily disabled
Array accelerator board has
been temporarily disabled.
Check the Disable Code field.
Accelerator status:
Unrecognized status
A status returned from the
array accelerator board that
DAAD does not recognize.
Call your Authorized Compaq Reseller for the
latest copy of DAAD.