D-3
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Switches and Jumpers Comments:
File Name: N-appd.doc Last Saved On: 4/24/97 10:49 AM
Setting NIC Switches
SW2 controls the network frequency of the optional ProLiant 800 100 Mb/s
Network Adapter module.
Placing all the SW2 switches in the ON position places the integrated
NIC in the 10 Mb/s mode.
Placing the switches in the OFF position activates the 100 Mb/s
option, if installed.
The ProLiant 800 server comes standard with the 10 Mb/s and requires the
100 Mb/s option for this switch to be functional.
SCSI Device Jumper Settings
The 32-Bit Fast-SCSI-2 Controller requires that a SCSI ID be set for each
SCSI device. No two SCSI devices connected to the same SCSI controller can
have the same SCSI ID. If another SCSI device is connected to the same
controller, check its SCSI ID in the Compaq System Configuration Utility
before beginning the installation procedure for this additional drive.
The SCSI ID is set by jumpers ID 2, ID 1, and ID 0 located on each SCSI
device. Refer to the label on the Side Access Panel of your server for the
jumper settings of supported SCSI devices.