8-40
Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
Configuration signature
mismatch
Array accelerator board
configured for a different
array controller board.
Configuration signature on
array accelerator board
does not match the one
stored on the array
controller board.
To recognize the array accelerator board, run
the System Configuration Utility.
Controller
communication failure
occurred
Controller communication
failure occurred.
DAAD was unable to successfully issue
commands to the controller in this slot.
Controller detected.
NVRAM configuration not
present
EISA nonvolatile RAM does
not contain a configuration
for this controller.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Controller firmware
needs upgrading
Controller firmware is
below the latest
recommended version.
Run Options ROMPaq to upgrade the controller
to the latest firmware revision.
Controller firmware
needs upgrading (DAAD
Error 102)
Controller is correct,
however, IDA firmware
version should be greater
than 1.26.
Call your Authorized Compaq Reseller to obtain
the latest firmware.