8-8
Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1151-Com Port 1
Address Assignment
Conflict
2S
Both external and internal
serial ports are assigned
to COM1.
Run the System
Configuration Utility
and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S
Both external and internal
serial ports are assigned
to COM2, COM3, or
COM4.
Run the System
Configuration Utility
and correct.
1600-Server
Manager/R Failure
None
Server Manager/R board
failure. Error code
displays after error
message.
Run Diagnostics.
Replace failed
assembly or contact
your service provider
1610-Temperature
Violation Detected.
Waiting for system to
cool.
2S
Ambient system
temperature too hot.
Check fan in system
environment.
1611-Fan Failure
Detected
2S
Required fan not installed
or spinning.
Check fans.
1612-Primary Power
Supply Failure
2S
Primary power supply has
failed.
Replace power supply
as soon as possible.
1613-Low System
Battery
None
Real time clock system
battery is running low on
power.
Run Diagnostics.
Contact your service
provider.
1701-SCSI Controller
failure
None
A test on the Fast SCSI-2
Controller failed
Contact your service
provider.
continued