2-9
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Server Management Comments:
File Name: D-ch2.doc Last Saved On: 4/23/97 11:14 AM
Critical Error Log Messages
continued
Error Message
Description
NMI- Automatic Server Recovery
Timer Expiration
The operating system has received notice of an
impending ASR-2 timer expiration.
Required System Fan Failure
The required system fan has failed. Accompanying
data in the log notes if an auto-shutdown sequence
has been invoked by the operating system.
UPS A/C Line Failure Shutdown or
Battery Low
The UPS notified the operating system that the AC
power line has failed. Accompanying data indicates if
an auto-shutdown sequence has been invoked or if
the battery has been nearly depleted.
Revision History Table
Some errors can be resolved by reviewing changes to the server’s
configuration. The server has an Automatic Revision Tracking (ART) feature
that helps you review recent changes to the server's configuration.
One ART feature is the Revision History Table, which contains the hardware
version number of the system board and any other system boards providing
ART-compatible revision information. This feature lets you determine the
level of functionality of an assembly in a system without opening or powering
down the unit.