Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-26
ASR-2 IML or Critical Error Log Messages
continued
Message Description
Caution: Temperature Exceeded
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
Diagnostic Error
An error was detected by the Diagnostics Utility. See the specific error code
in this chapter for a detailed explanation.
Error Detected On Boot Up
The server detected an error during the Power-On Self-Test (POST).
Processor Prefailure
A CPU has passed an internal corrected error threshold; excessive internal
ECC cache errors.
NMI - PCI Bus Parity Error
A parity error was detected on the PCI bus.
NMI - Expansion Board Error
A board on the expansion bus indicated an error condition, resulting in a
server failure.
NMI - Expansion Bus Master
Time-Out
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
NMI - Expansion Bus Slave
Time-Out
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
NMI - Fail-Safe Timer Expiration
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
Processor Exception
The indicated processor exception occurred.
NMI - Processor Parity Error
The processor detected a data error, resulting in a server failure.
Server Manager Failure
An error occurred with the Server Manager/R.
NMI - Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Caution: Temperature Exceeded
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
Abnormal Program Termination
The operating system has encountered an abnormal situation that has
caused a system failure.
ASR-2 Test Event
The System Configuration Utility generated a test alert.
NMI- Automatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer
expiration.
Required System Fan Failure
The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
UPS A/C Line Failure Shutdown
or Battery Low
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates if an auto-shutdown sequence has been
invoked or if the battery has been nearly depleted.
ASR-2 detected by ROM
An ASR-2 activity has been detected and logged by the system ROM.