3-34
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
6700 – 6799, SCSI Tape Drive Test Error Codes
The 6700 series of Diagnostic error codes identifies failures with tape cartridges, tape drives,
media changers, tape drive cabling, adapter boards, or the system board assembly.
Table 3-18
SCSI Tape Drive Test Error Codes
Error Code
Description
Recommended Action
6700-xx
SCSI Tape ID drive types test failed.
6706-xx
SCSI Disk SA/Media test failed.
6709-xx
SCSI Disk Erase tape test failed.
6728-xx
Media load/unload test failed.
1. Run the System Configuration Utility and
verify the drive type.
2. Replace the SCSI Tape drive signal and
power cables and retest.
3. Replace the SCSI controller and retest.
4. Replace the SCSI Tape drive and retest.
5. Replace the system board and retest.
7000 – 7099, Server Manager/R Board Test Error Codes
The 7000 series of Diagnostic error codes identifies failures with the Server Manager/R board.
Table 3-19
Server Manager/R Board Test Error Codes
Error Code
Description
Recommended Action
7000-11
Processor (80186 Timer).
7000-12
Processor (80186 Registers).
7000-13
Processor (Watch Dog Timer).
7000-14
Processor (8570 RAM).
7000-15
Processor (8570 RTC).
7000-21 Memory.
7000-22 Memory
Write/Read.
7000-23 Memory
Address.
7000-24
Memory Refresh Alert.
7000-25 Memory
Increment.
Replace the Server Manager/R board and retest.
continued
Summary of Contents for 5500R - ProLiant - 256 MB RAM
Page 6: ......