3-12
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1618-PCI slots
powered down.
Check PCI hot plug
enabler connectors.
None
PCI hot plug enabler is missing or
failed.
Check and replace missing or
failed assembly.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None
SCSI bus failure.
Run Diagnostics. Replace failed
assembly as indicated.
1621-Current SCSI
bus cable
configuration is not
recommended
None
Improper SCSI bus cabling.
Check documentation for proper
SCSI bus cabling.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling.
Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720-Slot x Drive
Array – SMART Drive
Detects Imminent
Failure SCSI: Port y:
SCSI ID x
None
Pre-failure condition.
Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future. If drive is part
of a non-fault-tolerant
configuration, back up all data
before replacing drive and
restore all data afterwards. If
drive is part of a fault-tolerant
configuration,
do not
replace
drive unless all other drives in
array are on-line. Press
F1
to
resume.
1724-Slot x Drive
Array – Physical
Drive Position
Change(s) Detected –
Logical drive
configuration has
automatically been
updated
None
Drive change.
Indicates that logical drive
configuration has been updated
automatically following physical
drive position changes. Press
F1
to resume.
continued
Summary of Contents for 5500R - ProLiant - 256 MB RAM
Page 6: ......