3-20
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1798-Drive Array -
Array Accelerator
Write Error Occurred.
Array Accelerator is
disabled.
None
Hard parity error while writing
data to posted-writes memory.
Enable Array Accelerator.
1799-Drive Array -
Drive(s) Disabled due
to Array Accelerator
Data Loss.
Select "F1" to
continue with logical
drives disabled.
Select "F2" to accept
data loss and to re-
enable logical drives.
None
Volume failed due to loss of data
in posted-writes memory.
Press
F1
to continue with
logical drives disabled or
F2
to
accept data loss and re-enable
logical drive.
Beeps only: 2 Long
2L
No valid memory is present in
the system.
Replace failed memory with
valid memory.
Beeps only: 2 Long +
2 Short
2L, 2S
Power is cycled. Temperature too
hot. Processor fan either not
installed or not spinning.
Check fans.
(Run System
Configuration Utility -
F10
key)
None
A configuration error occurred
during POST.
Press
F10
to run System
Configuration Utility.
(RESUME -
F1
key)
None
As indicated to continue.
Press
F1
Summary of Contents for 5500R - ProLiant - 256 MB RAM