3-16
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1781-Disk 1 Failure
None
Hard drive/format error.
Run Diagnostics. Replace failed
assembly as indicated.
1782-Disk Controller
Failure
None
Hard disk drive circuitry error.
Run Diagnostics. Replace failed
assembly as indicated.
1783-Slot x Drive
Array Controller
Failure
None
ROM installation problem or
Array Accelerator board problem.
If this message appears
immediately following a ROM
installation, the ROM is
defective or not installed
properly. Check to see if the
Array Accelerator board is
attached properly. Check that
the array controller is firmly
inserted in its slot. Try
upgrading the System ROMs.
Otherwise, replace the Smart
Array Controller.
1784-Drive Array
Drive Failure,
Physical Drive
None
Defective drive and/or cables.
Check for loose cables. Replace
defective drive
X
and/or
cable(s).
1785-Drive Array not
Configured
None Configuration
error.
Run Compaq
Array
Configuration
Utility
1. Run the Compaq Array
Configuration Utility.
No drives
detected.
2. Turn off system and check
SCSI cable connections to
make sure drives are
attached properly.
Array
Accelerator
Memory Size
Increased.
3. Run the Compaq System
Configuration Utility.
External
Cable(s)
Attached to
Wrong SCSI
Port
Connector(s).
4. Turn system power OFF
and swap SCSI power
connectors to prevent data
loss.
Drive positions
cannot be
changed during
Capacity
Expansion.
5. Run Array Diagnostic
Utility if previous positions
are unknown. Then turn
system power OFF and
move drives to their
original positions.
continued
Summary of Contents for 5500R - ProLiant - 256 MB RAM
Page 6: ......