Diagnostic Tools
3-25
For use with Pentium II and Pentium III Xeon processor-based servers only
500 – 599, Video Display Unit Test Error Codes
The 500 series of Diagnostic error codes identifies failures with video or system board
functions.
Table 3-7
Video Display Unit Test Error Codes
Error Code
Description
Recommended Action
501-xx
Video controller test failed.
502-xx
Video memory test failed.
503-xx
Video attribute test failed.
504-xx
Video character set test failed.
505-xx
Video 80 x 25-mode 9 x 14
character cell test failed.
506-xx
Video 80 x 25-mode 8 x 8
character cell test failed.
507-xx
Video 40 x 25-mode test failed.
508-xx
Video 320 x 200-mode color set 0
test failed.
509-xx
Video 320 x 200-mode color set 1
test failed.
510-xx
Video 640 x 200-mode test failed.
511-xx
Video screen memory page test
failed.
512-xx
Video gray scale test failed.
514-xx
Video white screen test failed.
516-xx
Video noise pattern test failed.
1. Replace the monitor and retest.
2. Replace the Advanced VGA board and retest.
3. Replace the system board and retest.