![Compaq Storageworks SAN Switch 8 Installation And Hardware Manual Download Page 68](http://html1.mh-extra.com/html/compaq-storageworks/san-switch-8/san-switch-8_installation-and-hardware-manual_2646671068.webp)
Error Messages
5-13
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide Comments:
Part Number: EK-BCP24-IA / 161355-001 File Name: F-CH5 ERROR MESSAGES.DOC Last Saved On: 9/30/99 10:29 AM
Table 5-3
Diagnostic Error Messages
continued
Message
Description
Probable Cause
Action
DIAG-
REGERR_UNRST
Err#0B16, 0416
[portRegTest,
sramRetentionTest]
A port failed to unreset.
ASIC failure
Replace motherboard
assembly
DIAG-STATS
Err#2660-2662,
3060 -3062
[portLoopback Test,
crossPortTest]
The port counter value did not
match the number of frames
actually transmitted. Possible
counters reporting:
■
FramesTx - number of
frames transmitted
■
FramesRx - number of
frames received
■
Cl3FrmRx - number of
Class 3 frames received
ASIC, GBIC
module, or fiber
cable failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-TIMEOUT
Err#266F, 306F,
386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
For portLoopbackTest and
crossPortTest: A port failed to
receive a frame within the time
out period.
For centralMemoryTest: A port
failed to detect an interrupt
within the time out period.
ASIC, GBIC
module, or fiber
cable failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-XMIT
Err#2271, 2671,
3071, 3871
[portLoopbackTest,
crossPortTest,
spinSilk, camTest]
A port failed to transmit a frame.
ASIC failure
Replace motherboard
assembly
CONFIG CORRUPT
The switch configuration
information has become
irrevocably corrupted.
OS error
The system resorts to
default configuration
settings
CONFIG OVERFLOW
The switch configuration
information has grown too large
to be saved or has an invalid
size.
OS error
Contact customer
support
continued