Table 5-3
Diagnostic Error Messages
continued
Message
Description
Probable Cause
Action
DIAG-DATA
Err#266E, 306E
[portLoopbackTest,
crossPortTest]
The payload received by a port
did not match the payload
transmitted.
motherboard,
GBIC module, or
fiber cable
failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-ERRSTAT
Err#2640-2647,
3040- 3047,
3840-3847
[portLoopbackTest,
crossPortTest,
spinSilk]
The Port Error Statistics counter
is non-zero, meaning an error
was detected when receiving
frames. One of the following
status errors occurred.
■
Enc_in
– Encoding error,
inside frame
■
CRC_err
– Cyclic
redundancy check on frame
failed
■
TruncFrm
– Truncated
frame
■
FrmTooLong
– Frame too
long
■
BadEOF
– Bad end of file
■
Enc_out
– Encoding error,
outside frame
■
BadOrdSet
– Bad symbol on
fiber-optic cable
■
DiscC3
– Discarded Class 3
frames
ASIC,
motherboard,
GBIC module, or
fiber cable
failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-INIT
Err#264F, 304F,
384F
[portLoopbackTest,
crossPortTest,
spinSilk]
A port failed to activate in the
loopback mode requested.
ASIC,
motherboard,
GBIC module, or
fiber cable
failure
Replace motherboard
assembly, GBIC
module, or fiber cable
continued