INS_CWGE24MS2_REV–
10/05/16 PAGE 266
INSTALLATION AND OPERATION MANUAL
CWGE24MS2
TECH SUPPORT: 1.888.678.9427
Mail Alarm
Introduction
The feature sends an e-mail trap to a predefined administrator when some events occur. The
events are listed below:
» System Reboot
: The system warn start or cold start.
» Port Link Change
: A port link up or down.
» Configuration Change
: The system configurations in the NV-RAM have been updated.
» Firmware Upgrade
: The system firmware image has been updated.
» User Login
: A user login the system.
» Port Blocked
: A port is blocked by looping detection or BPDU Guard.
Default Settings
Mail-Alarm Configuration:
-----------------------------------------------
State
: Disabled.
Server IP
: 0.0.0.0
Server Port
: 25
Mail From
:
Mail To
:
Trap Event Status:
-----------------------------------------------
System Reboot
: Disabled.
Port Link Change
: Disabled.
Configuration Change
: Disabled.
Firmware Upgrade
: Disabled.
User Login
: Disabled.
Port Blocked
: Disabled.
Alarm
: Disabled.