![Comnet CNGE8FX4TX4MS Installation And Operation Manual Download Page 19](http://html1.mh-extra.com/html/comnet/cnge8fx4tx4ms/cnge8fx4tx4ms_installation-and-operation-manual_2644370019.webp)
13
Ports
RJ45 ports (Auto MDI/MDIX)
: The RJ45 ports are auto-sensing for 10Base-T, 100Base-TX
or 1000Base-T device connections. Auto MDI/MDIX means that you can connect to another
switch or workstation without changing straight through or crossover cabling. See figures
below for straight-through and crossover cable schematic.
RJ45 Pin Assignments
Pin Number
Assignment
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Note
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
All ports on this managed switch support automatic MDI/MDI-X operation. You can use
straight-through cables (See Figure below) for all network connections to PCs or servers, or
to other switches or hubs. In a straight-through cable, pins 1, 2, 3, and 6, at one end of the
cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The
10BASE-T/100BASE-TX/1000BASE-T MDI and MDI-X port pin outs are as presented below.
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)