PoE Configuration - Power management Mode
There are 2 modes for configuring when to the ports is shut down.
Label
Description
Actual
Consumption
In this mode the ports are shut down when the actual power
consumption for all ports exceeds the amount of power that the
power supply can deliver or if the actual power consumption for a
given port exceeds the reserved power for that port. The ports are
shut down according to the ports priority. If two ports have the same
priority the port with the highest port number is shut down.
Reserved Power In this mode the ports are shut down when total reserved powered
exceeds the amount of power that the power supply can deliver. In
this mode the port power is not turned on if the PD requests more
power the available.