inS_CnGE28FX4TX_rEv–
08/31/12 PAGE 19
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX
Tech SupporT: 1.888.678.9427
Label
Description
System Contact The text identification of the contact person for this managed
node, together with information on how to contact this person. The
allowed string length is 0 to 255, and the allowed content is the ASCII
characters from 32 to 126.
System Name
An administratively assigned name for this managed node. By
convention, this is the node’s fully qualified domain name. A domain
name is a text string drawn from the alphabet (A-Z, a-z), digits (0-9),
minus sign (-). No space characters are permitted as part of a name.
The first character must be an alpha character. And the first or last
character must not be a minus sign. The allowed string length is 0 to
255.
System Location The physical location of this node(e.g., telephone closet, 3rd floor).
The allowed string length is 0 to 255, and the allowed content is the
ASCII characters from 32 to 126.
Timezone Offset Enter the name of contact person or organization
Provide the time zone offset relative to UTC/GMT.
The offset is given in minutes east of GMT. The valid range is from
-720 to 720 minutes.
Save
Select to save changes.
Reset
Select to undo any changes made locally and revert to previously
saved values.
Admin & Password
This page allows you to configure the system password required to access the web pages or log
in from CLI.
Label
Description
Old Password
Enter the current system password. If this is incorrect, the new
password will not be set.
New Password The system password. The allowed string length is 0 to 31, and the
allowed content is the ASCII characters from 32 to 126.
Confirm
password
Re-type the new password.
Save
Select to save changes.