background image

INSTALLATION AND OPERATION MANUAL 

CNGE28FX4TX

(24) 10/100/1000 BASE-TX + (4) 1000BASE-FX   

wiTh PowEr ovEr EThErnET (PoE)

v1.4 Sept 2012

The ComNet

 CNGE28FX4TX Managed Redundant Ring Ethernet Switch 

provides robust transmission of (24) 10/100/1000BASE-T(X) ports and (4) 1000BASE-
FX ports of Ethernet data. Fully compliant with IEEE 802.3at, up to 720 watts of PoE or 
PoE+ power is available for distribution across all 24 Base-TX ports. The four 1000BASE-
FX ports may be used with multimode or single-mode optical fiber when used with 
ComNet SFPs. The exclusive C-Ring protects mission-critical applications from network 
interruptions or temporary malfunctions with its fast recovery technology. eConsole, 
a powerful, easy-to-use Windows-based utility, allows the CNGE28FX4TX 
to be centrally managed. Diverse media selection provides for easy implementation 
of point-to-point, linear add-drop, drop-and-repeat, star, or true self-healing ring and 
mesh network system architectures. The electrical ports support the 10/100/1000Mbps 
Ethernet IEEE802.3 protocol, and auto-negotiating and auto-MDI/MDIX features 
are included for simplicity and ease of installation. These network-managed layer 2 
switches are optically (1000BASE-FX) and electrically compatible with any IEEE802.3 
compliant Ethernet device. Unlike most Ethernet switches, the environmentally 
hardened  CNGE28FX4TX is designed for direct deployment in difficult 
out-of-plant or roadside operating environments. Featuring a low-profile 1-RU high 
rack-mountable package, these units may be mounted within any standard 19-inch 
rack cabinet, and the high-capacity power supply for operation of the switch and PoE 
PSE (Power Sourcing Equipment) is completely self-contained.

Summary of Contents for CNGE28FX4TX24MSPOE+

Page 1: ...8FX4TX24MSPOE to be centrally managed Diverse media selection provides for easy implementation of point to point linear add drop drop and repeat star or true self healing ring and meshnetworksystemarc...

Page 2: ...view 4 Introduction 4 Software Features 5 Hardware Features 6 Hardware Overview 7 Front Panel 7 Rear Panel 8 Rack mount kit assembly 9 Front Panel LEDs 10 Cables 11 Ethernet Cables 11 100BASE TX 10BAS...

Page 3: ...properly installed or damaged by accidents Please refer to the Technical Specifications section for the actual warranty period s of the product s associated with this publication Disclaimer Informatio...

Page 4: ...P police function can only permit allowed IP address with MAC address to access the networking Hacker cannot access the IP surveillance network without permission It can avoid hackers from stealing vi...

Page 5: ...port Power supply included Supports IP based bandwidth management Supports application based QoS management Supports IP police security function Supports DOS DDOS auto prevention IGMP v2 v3 IGMP snoo...

Page 6: ...8 9427 Hardware Features One 100 240VAC power input for CNGE28FX4TX24MSPOE Operating Temperature 40 to 75 C Storage Temperature 40 to 85 C Operating Humidity 5 to 95 non condensing Casing IP 20 24 10...

Page 7: ...RJ45 Auto MDI MDIX with PSE Console Use RS 232 with DB 9 connecter to manage switch 1 2 3 4 5 6 7 8 8 CNGE28FX4TX24MSPOE Front Panel 1 Console port DB 9 2 10 100 1000BASE T X gigabits Ethernet ports...

Page 8: ...ing mode Blinking indicates Ring is broken System Running Indicator RUN System operated continuously Supervisor Login Indicator RMT System is accessed remotely Reset To Default Running Indicator DEF S...

Page 9: ...STALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Rack mount kit assembly You can find the rack mount kit and the screws in the packing box Please assembly the rack mount...

Page 10: ...erated in C Ring Master mode Ring C Ring Green Indicate system operated in C Ring mode Blinking Ring is broken RUN Sysem Running Green System operated continuously RMT Supervisor Login Green System is...

Page 11: ...ble specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 UTP 100m 328ft RJ 45 100BASE TX Cat 5 100 UTP UTP 100m 328ft RJ 45 1000BASE TX Cat 5 Cat 5e 100...

Page 12: ...E Power input 7 BI_DD 8 BI_DD The CNGE28FX4TX24MSPOE switch will support auto MDI MDI X operation You can use a straight through cable to connect a PC to the switch The following table below shows the...

Page 13: ...BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Note and signs represent the polarity of the wires that make up each wire pair SFP The Switch has fiber optical ports with SFP conne...

Page 14: ...1 12 PAGE 14 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Console Cable The CNGE28FX4TX24MSPOE switch can be managed by a PC connected to the console port using the...

Page 15: ...nsmitted Data Transmitted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Transmitted from DTE Device DTE Ready Received by DCE Device 5...

Page 16: ...features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explore...

Page 17: ...78 9427 System Login 1 Launch Internet Explorer 2 Type http 192 168 10 1 and the IP address of the switch Press Enter 3 The login screen appears 4 Enter username and password The default username and...

Page 18: ...GE 18 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Main Interface Main interface 4 1 2 Basic Setting 4 1 2 1 System Information The switch system information is pro...

Page 19: ...string length is 0 to 255 System Location The physical location of this node e g telephone closet 3rd floor The allowed string length is 0 to 255 and the allowed content is the ASCII characters from...

Page 20: ...ling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column The default IP is 192 168 10 1 IP Mask Assign the...

Page 21: ...tomatic redirect web browser to HTTPS during HTTPS mode enabled Possible modes are Enabled Enable HTTPS redirect mode operation Disabled Disable HTTPS redirect mode operation Save Select to save chang...

Page 22: ...LDP frame shall be considered valid The LLDP information valid period is set to TX Hold multiplied by TX Interval seconds Valid values are restricted to 2 10 times TX Delay If some configuration is ch...

Page 23: ...nto the LLDP Chassis ID field CDP TLV Address is mapped into the LLDP Management Address field The CDP address TLV can contain multiple addresses but only the first address is shown in the LLDP neighb...

Page 24: ...sed by the neighbor unit Port Description Port Description is the port description advertised by the neighbor unit System Capabilites System Capabilities describes the neighbor unit s capabilities The...

Page 25: ...s Label Description Neighbor entries were last changed at Shows the time for when the last entry was last deleted or added It is also shows the time elapsed since last change was detected Total Neighb...

Page 26: ...ined within the table Entries are removed from the table when a given port links down an LLDP shutdown frame is received or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple...

Page 27: ...ion You can save view or load the switch configuration The configuration file is in XML format with a hierarchy of tags Firmware Update This page facilitates an update of the firmware controlling the...

Page 28: ...ient information and display in here DHCP Client List You can assign the specific IP address that is in the assigned dynamic IP range to the specific port When the device is connecting to the port and...

Page 29: ...itted The Rx and TX settings are determined by the result of the last Auto Negotiation Check the configured column to use flow control This setting is related to the setting for Configured Link Speed...

Page 30: ...Policer Unit is kbps and it is restricted to 1 1000 when the Policer Unit is Mbps Policer Unit Configure the unit of measure for the port policer rate as kbps or Mbps The default value is kbps Shaper...

Page 31: ...ddress is enabled Destination MAC Address The Destination MAC Address can be used to calculate the destination port for the frame Check to enable the use of the Destination MAC Address or uncheck to d...

Page 32: ...Group ID Normal indicates there is no aggregation Only one group ID is valid per port Port Members Each switch port is listed for each group ID Select a radio button to include a port in an aggregati...

Page 33: ...port from the aggregation By default no ports belong to any aggregation group Only full duplex ports can join an aggregation and ports must be in the same speed in each group Key The Key value incurr...

Page 34: ...id is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID La...

Page 35: ...port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled Key The key assigned to this port Only ports with the same key can aggregate togethe...

Page 36: ...llegal LACP frames have been discarded at each port Refresh Select to refresh the page immediately Auto refresh Check this box to enable an automatic refresh of the page at regular intervals Clear Cle...

Page 37: ...be used to divide a big ring into two smaller rings to avoid effecting all switches when network topology change It is a good application for connecting two Rings Coupling Port Link to Coupling Port...

Page 38: ...the failure The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If th...

Page 39: ...The maximum age of the information transmitted by the Bridge when it is the Root Bridge Valid values are in the range 6 to 40 seconds and MaxAge must be FwdDelay 1 2 Maximum Hop Count This defines the...

Page 40: ...rder to share spanning trees for MSTI s Intra region The name is at most 32 characters Configuration Revision The revision of the MSTI configuration named above This must be an integer between 0 and 6...

Page 41: ...ibly change them as well Label Description MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numerical values have better pri...

Page 42: ...AL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 CIST Ports This page allows the user to inspect the current STP CIST port configurations and possibly change them as well This page contains settings...

Page 43: ...e port or not Restricted Role If enabled causes the port not to be selected as Root Port for the CIST or any MSTI even if it has the best spanning tree priority vector Such a port will be selected as...

Page 44: ...ettings are stack global Label Description Port The switch port number of the corresponding STP CIST and MSTI port Path Cost Controls the path cost incurred by the port The Auto setting will set the p...

Page 45: ...ridge ID The Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently assigned the root port role Root Cost Root Path Cost For t...

Page 46: ...logical STP port CIST Role The current STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort State The current STP port stat...

Page 47: ...on BPDU s received transmitted on the port STP The number of legacy STP Configuration BPDU s received transmitted on the port TCN The number of legacy Topology Change Notification BPDU s received tran...

Page 48: ...save VLAN ID The VLAN ID for the entry MAC Address The MAC address for the entry Port Members Checkmarks indicate which ports are members of the entry Check or uncheck as needed to modify the entry Ad...

Page 49: ...OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Example Portbased VLAN Setting For ingress port 1 VLAN Membership Configuration setting port 1 VID 50 2 VLAN Port 1 Configurations Disab...

Page 50: ...PERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port 2 VID 50 2 VLAN Port 2 Configuration don t care VLAN Aware 3 VLAN Port 2 Con...

Page 51: ...ION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 802 1Q Access port Setting For ingress port 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configurations Enable VLAN Aware 1...

Page 52: ...RATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configurations Disable VLAN Aware 3 VLAN Port Configuration...

Page 53: ...g CNGE28FX4TX24MSPOE CNGE28FX4TX24MSPOE PC B PC A P1 P2 P6 P5 For ingress port 1 VLAN Membership Configuration setting port VID 11 22 33 2 VLAN Port Configurations Enable VLAN Aware 3 VLAN Port Config...

Page 54: ...X24MSPOE Tech Support 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port VID 11 22 33 2 VLAN Port Configurations Enable VLAN Aware 3 VLAN Port Configuration Mode none Egress p...

Page 55: ...28FX4TX24MSPOE Tech Support 1 888 678 9427 QinQ VLAN Setting CNGE28FX4TX24MSPOE PC PC P3 P1 P2 Tag 50 tag 77 packet ingress Port 1 egress Port 2 For Ingress port Port 1 1 VLAN Membership Configuration...

Page 56: ...ON AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 3 VLAN Port Configuration Port 1 Mode specific ID 50 For egress port Port 2 1 VLAN Membership Configuration setting port VID 50 2...

Page 57: ...VLANs can be added or deleted here Port members of each Private VLAN can be added or removed here Private VLANs are based on the source port mask and there are no connections to VLANs This means that...

Page 58: ...Adding a New Static Entry Select Add New Private VLAN to add a new private VLAN ID An empty row is added to the table and the private VLAN can be configured as needed The allowed range for a private...

Page 59: ...the allowed content is the ASCII characters from 33 to 126 The field only suits to SNMPv1 and SNMPv2c SNMPv3 is using USM for authentication and privacy and the community string will associated with S...

Page 60: ...hexadecimal digits with a colon separates each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of c...

Page 61: ...omatically Otherwise the ID specified in this field is used The string must contain an even number between 10 and 64 hexadecimal digits but all zeros and all F s are not allowed Trap Security Name Ind...

Page 62: ...X24MSPOE _REV 08 31 12 PAGE 62 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 SNMP Users Configure SNMPv3 users table on this page The entry index keys are Engine ID...

Page 63: ...e security models are NoAuth NoPriv None authentication and none privacy Auth NoPriv Authentication and none privacy Auth Priv Authentication and privacy The value of security level cannot be modified...

Page 64: ...el Indicates the security model that this entry should belong to Possible security models are v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Name A string i...

Page 65: ...allowed content is the ASCII characters from 33 to 126 View Type Indicates the view type that this entry should belong to Possible view types are included An optional flag to indicate that this view s...

Page 66: ...elong to Possible security models are any Accepted any security model v1 v2c usm v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Level Indicates the security...

Page 67: ...SCP or Tag Priority Frames not matching any of the QCEs are classified to the default QoS class for the port Port QoS Configuration Label Description Port A check box is provided for each port of a pr...

Page 68: ...QoS classes Low Normal Medium and High The classification is controlled by a QoS assigned to each port A QCL consists of an ordered list of up to 12 QCEs Each QCE can be used to classify certain fram...

Page 69: ...SCP IPv4 and IPv6 DSCP ToS The 3 precedence bit in the ToS byte of the IPv4 IPv6 header also known as DS field Tag Priority User Priority Only applicable if the frame is VLAN tagged or priority tagged...

Page 70: ...opackets per second The configuration indicates the permitted packet rate for unicast multicast or broadcast traffic across the switch Note Frames which are sent to the CPU of the switch are always li...

Page 71: ...everal types according to different QCL policies Set up Typical Network Application Rules Set up the specific QCL for different typical network application quality control Set up ToS Precedence Mappin...

Page 72: ...ble the per VLAN IGMP Snooping IGMP Querier Enable the IGMP Querier in the VLAN The Querier will send out if no Querier received in 255 seconds after IGMP Querier Enabled Each Querier s interval is 12...

Page 73: ...f the entry Querier Status Show the Querier status is ACTIVE or IDLE Querier Receive The number of Transmitted Querier V1 Reports Receive The number of Received V1 Reports V2 Reports Receive The numbe...

Page 74: ...to apply to this port The allowed values are Disabled or the values 1 through 15 The default value is Disabled Port Copy Select which port frames are copied to The allowed values are Disabled or a sp...

Page 75: ...NSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 802 1x This page allows you to configure how an administrator is authenticated when he logs into the switch stack via TE...

Page 76: ...lues Common Server Configuration These setting are common for all of the Authentication Servers Label Description Timeout The Timeout which can be set to a number between 3 and 3600 seconds is the max...

Page 77: ...ntication servers are alive the local user database is used for authentication This is only possible if the Authentication Method is set to something else than none or local Port The UDP port to use o...

Page 78: ...o that the user cannot change it An example of such a module is the MAC Based Authentication under 802 1X Each port can do learning based upon the following settings Label Description Auto Learning is...

Page 79: ...he entry Check or uncheck as needed to modify the entry Adding a New Static Entry Select Add new static entry to add a new entry to the static MAC table Specify the VLAN ID MAC address and port member...

Page 80: ...t Frames transmitted are not mirrored TX only Frames transmitted from this port are mirrored to the mirror port Frames received are not mirrored Disabled Neither frames transmitted nor frames received...

Page 81: ...rror level of the system log All All levels Time The time of the system log entry Message The MAC Address of this switch Auto refresh Check this box to enable an automatic refresh of the page at regul...

Page 82: ...ge The detailed messages of the system log entry Refresh Updates the system log entries starting from the current entry ID Clear Flushes all system log entries Updates the system log entries starting...

Page 83: ...and transmitted packets per port Bytes The number of received and transmitted bytes per port Errors The number of frames received in error and the number of incomplete transmissions per port Drops Th...

Page 84: ...s This page provides detailed traffic statistics for a specific switch port Use the port select box to select which switch port details to display The displayed counters are the totals for receive and...

Page 85: ...ted on this port that have an opcode indicating a PAUSE operation Rx Drops The number of frames dropped due to lack of receive buffers or egress congestion Rx CRC Alignment The number of frames receiv...

Page 86: ...ally until responses to all packets are received or until a timeout occurs PING6 server 10 10 132 20 64 bytes from 10 10 132 20 icmp_seq 0 time 0ms 64 bytes from 10 10 132 20 icmp_seq 1 time 0ms 64 by...

Page 87: ...he page refreshes automatically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will...

Page 88: ...automatic determines how much power to reserve according to the class the connected PD belongs to and reserves the power accordingly Three different port classes exist and one for 4 7 and 15 4 Watts...

Page 89: ...r all ports exceeds the amount of power that the power supply can deliver or if the actual power consumption for a given port exceeds the reserved power for that port The ports are shut down according...

Page 90: ...ies One is used as primary power source and one as backup power source In case that the primary power source fails the backup power source will take over For being able to determine the amount of powe...

Page 91: ...There are three levels of power priority named Low High and Critical The priority is used in the case where the remote devices require more power than the power supply can deliver In this case the po...

Page 92: ...l Description Local Port This is the logical port number for this row Power Reserved The Power Reserved shows how much the power the PD has reserved Power Used The Power Used shows how much power the...

Page 93: ...ice is a PD device it can either run on its local power supply or it can use the PSE as power source It can also use both its local power supply and the PSE If it is unknown what power supply the PD d...

Page 94: ...nfiguration is retained Label Description Yes Select to reset the configuration to Factory Defaults No Select to return to the Port State page without resetting the configuration System Reboot You can...

Page 95: ...ou can use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before Configuring by RS 232 serial console use an DB 9 M to DB 9 F cable to conne...

Page 96: ...TALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Step 3 Select to use COM port number Step 4 The COM port properties setting 115200 for baud rate 8 for Data bits None for...

Page 97: ...7 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427 Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password The same with the pas...

Page 98: ...P Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address o...

Page 99: ...TX24MSPOE Tech Support 1 888 678 9427 Commander Groups System System Configuration all port_list Reboot Restore Default keep_ip Contact contact Name name Location location Description description Pass...

Page 100: ...time RADIUS server_index enable disable ip_addr_string secret server_port ACCT_RADIUS server_index enable disable ip_addr_string secret server_port Client console telnet ssh web none local radius enab...

Page 101: ...Tech Support 1 888 678 9427 Aggr Aggr Configuration Add port_list aggr_id Delete aggr_id Lookup aggr_id Mode smac dmac ip port enable disable LACP LACP Configuration port_list Mode port_list enable d...

Page 102: ...rt_list enable disable Port AutoEdge port_list enable disable Port P2P port_list enable disable auto Port RestrictedRole port_list enable disable Port RestrictedTcn port_list enable disable Port bpduG...

Page 103: ...ding enable disable Groups vid Status vid LLDP LLDP Configuration port_list Mode port_list enable disable rx TX Optional_TLV port_list port_descr sys_name sys_descr sys_ capa mgmt_addr enable disable...

Page 104: ...ist enable disable QOS QoS Configuration port_list Classes class Default port_list class Tagprio port_list tag_prio QCL Port port_list qcl_id QCL Add qcl_id qce_id qce_id_next etype etype vid vid port...

Page 105: ...switch port port policy policy vid tag_prio dmac_type etype etype smac dmac arp sip dip smac arp_opcode arp_flags ip sip dip protocol ip_flags icmp sip dip icmp_type icmp_code ip_flags udp sip dip sp...

Page 106: ...id user_name MD5 SHA auth_password DES priv_password User Delete index User Changekey engineid user_name auth_password priv_ password User Lookup index Group Add security_model security_name group_nam...

Page 107: ...EE 802 1w for RSTP Rapid Spanning Tree Protocol IEEE 802 1s for MSTP Multiple Spanning tree Protocol IEEE 802 1x for Authentication IEEE 802 1AB for LLDP Link Layer Discovery Protocol IEEE 802 3at PoE...

Page 108: ...ready Blinking for system is upgrading firmware Ring Master Indicator R M Green Indicate system operated in C Ring Master mode C Ring Indicator Ring Green Indicate system operated in C Ring mode Blink...

Page 109: ...0 to 85 C 40 to 185 F Operating Temperature 40 to 75 C 40 to 167 F Operating Humidity 5 to 95 Non condensing Regulatory approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3...

Page 110: ...INS_CNGE28FX4TX24MSPOE _REV 08 31 12 PAGE 110 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427...

Page 111: ...INS_CNGE28FX4TX24MSPOE _REV 08 31 12 PAGE 111 INSTALLATION AND OPERATION MANUAL CNGE28FX4TX24MSPOE Tech Support 1 888 678 9427...

Page 112: ...ch Support 1 888 678 9427 info comnet net 8 Turnberry Park Road Gildersome Morley Leeds UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 info Europe comnet net MECHANICAL INSTALLATION INSTRUCTIONS...