10 Communications
CommPact Installation Manual
73
10.8.3. Caller ID Mode and Incoming Number
Incoming number feature allows the engineer to program up to three high-priority telephone
numbers so that the user would be able to use Telecontrol/2-way audio over GSM during a GPRS
session. If the Control System recognizes the incoming call as a high-priority call, the GPRS session
will be suspended. Caller ID Mode option allows selection of the ID Mode applicable to your
specific network.
Caller ID Mode option affects PSTN too. There is no Caller ID Fail trouble for the incoming
calls over GSM.
To choose the applicable Caller ID Mode option:
1.
From the Programming menu, select Communications, Comm. Options, and Caller ID
Mode. [95416].
2.
Choose the mode applicable to your PSTN network (Bellcore, British Telecom, and
Japan). You can also disable Caller ID by choosing Caller ID Disable.
To program/edit the Incoming Number:
1.
From the Programming menu, select Communications, Comm. Options, and Incoming #.
[95417].
2.
Select the telephone number you want to edit (1-3).
3.
Enter up to 16 digits. Use the
key to enter "*", "#", "," (pause), "T" (switch to DTMF
tone dialing), "P" (switch to pulse dialing) or "+" (international code). Use the
key to
delete one character at a time. Press '
√ʹ
when you have finished editing.
10.8.4. Remote Firmware Update
Electronics Line 3000’s Remote Firmware Update feature allows the Engineer or service provider to
perform firmware update from a remote PC using WEB communication.
Before performing the firmware update, locally unset the system and make sure that there is
no AC LOSS or BATTERY LOW conditions.
To setup the firmware update mode:
1.
From the Programming menu, select Communications, Comm. Options, and Rem. SW
Update [95418].
2.
Select the Remote Firmware Update mode from the following table:
Table 10-2: Remote FW Update
Access option
Description
Always Enable
Update is always possible.
Disable
Firmware update is not allowed.
User Initiated
The user must perform SW Update from the Service menu in order to
establish a connection – see p. 33, 4.7.14 Remote Firmware Update.
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...