7 Devices
CommPact Installation Manual
43
7.3.4. Bell
(Sounder)
Each zone can be programmed to activate the sounder when triggered or to generate a silent alarm
where only a message is sent to the central station.
To program the Bell option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Bell [#05]; the zone’s current Bell setting is displayed.
4.
Select either Enabled or Disabled.
Fire zones always activate the sounder regardless of what is programmed for this
option.
If the bell is disabled for Panic zones, this also disables all forms of alarm indication
from the on-board keypad in the event of a Panic alarm.
If the Bell option is enabled for Environmental or Flood zones, the system sounds trouble
tones from the keypad.
7.3.5. Chime
When Chime is enabled, triggering the zone when the system is unset causes the Built-In Sounder
to chime.
To program the Chime option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Chime [#06]; the zone’s current Chime setting is
displayed.
4.
Select either Enabled or Disabled.
7.3.6. Force
Set
Force setting enables you to set the system when the system is not ready. For example, a door that
is protected by a magnetic contact is open. You may set the system on condition that the zone is
defined as Force Set enabled. This door must be closed by the end of the Exit delay otherwise an
alarm is generated. If the magnetic contact’s zone is defined as Force Set disabled, the system will
not be ready to set until you close the door.
To program the Force Set option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Force Set [#07]; the zone’s current Force Set setting is
displayed.
4.
Select either Enabled or Disabled.
For the Force Set feature to function, you must also enable Force Setting in System
Options -- see p. 53,
9.2.1 Forced .
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...