9 System Options
CommPact Installation Manual
53
9.
System Options
As the name suggests, System Options are settings that affect the entire system. This chapter offers
explanations and programming instructions for each of these options.
9.1. Code
Lockout
The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts are made to
enter the user code.
To program the Code Lockout setting:
1.
From the Programming menu, select System Options, Code Lockout [9401].
2.
Select Enabled or Disabled.
During the 30-minute lockout period, you can still set and unset the system using
keyfobs. If one key setting is enabled, you may still set the system using the keypads.
9.2. Set/Unset
Options
The options offered in this section relate to setting and unsetting the system.
9.2.1. Forced
Set
Forced setting enables you to set the system when the system is not ready. This option allows you
to enable or disable Forced setting for the entire system. Additionally, you can enable or disable
Forced setting for each individual zone. For further information, see p. 43,
7.3.6 Force .
To program the Forced Set:
1.
From the Programming menu, select System Options, Set/Unset and Forced Set [94021].
2.
Select Enabled or Disabled.
9.2.2. One-Key
Setting
You can set the system by pressing any of the three setting keys on the keypad. If One-Key Setting
is enabled, the system does not prompt you for a user code.
To program the One-Key Setting:
1.
From the Programming menu, select System Options, Set/Unset, and One-Key Setting
[94022].
2.
Select Enabled or Disabled.
9.2.3. Supervised
Set
The Supervised Set option is a feature designed to supervise a wireless device activity before you
set the system. If the system has not received a transmission from a detector during the interval
defined for this option, all setting methods that include that detector will not be available. Medical,
Panic, Fire, Gas, Flood, and Environmental zones are not included in this supervision and do not
affect the system’s ability to set.
Press
to check which detector is causing the "System Not Ready" condition.
To make the required setting method available, activate the detector. PIR detectors have a three-
minute delay between transmissions.
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...