3 Basic System Operation
CommPact Installation Manual
18
For this feature to function, Trouble Tones must be enabled in programming – see p. 51,
8.6.1 System Trouble Tones.
System trouble tones are not sounded from 10:00pm to 7:00am so as not to disturb household
members who may be asleep. However, you can program the system to immediately annunciate
telephone trouble at all times – see p. 51
8.6.2 Telephone Trouble Tones.
3.5.2.
Vocal Message Annunciation
Certain versions of the CommPact Control System hardware support vocal annunciation of system
status. If this feature is enabled in programming (see p. 59,
9.10 Vocal Messages), the system plays
short messages to indicate setting, unsetting, omitted zones, system trouble, message waiting, and
water alarm.
The availability of the Vocal Message annunciation feature is hardware dependent.
3.5.3.
Alarm Sounding Patterns
The following table summarizes the system’s various alarm patterns.
Table 3-7: Alarm Patterns
Alarm
Alarm Pattern Description
Sounding
Device
Burglary
ON (continuously)
Sounder
Fire
ON - ON - ON, 1.5-second pause, ON - ON – ON...
Sounder
Gas
ON - ON - ON - ON (short bursts), 5 second pauses, ON - ON - ON -
ON...
Sounder
Medical
ON (continuously) – only applicable for Medical alarm from zone
Sounder
Flood/
Environmental
4 rapid tones sounded once per minute (same as Trouble tones)
Buzzer
3.6.
Setting and Unsetting
The following section explains how to set and unset the Control System using the front panel
keypad or Wireless Keypad:
3.6.1. Setting
You have three setting modes available: full, part, and perimeter. Figure
3-3 illustrates the three
setting modes. In each diagram, the protected area is shaded.
Full Set
Part Set
Perimeter Set
Figure 3-3: Setting Modes
The setting options are entirely flexible. You can program each detector to be included in any
combination of the three setting modes – see p. 42,
7.3.2 Set. Additionally, each setting mode has a
separate exit and entry delay.
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...