Yellow Led activate, green Led off (

FAULT relay activates and 0 mA output signal

):

 this signal different kind of faults. 

1)

 The Dip-Switch set up is wrong, please verify (

see Tables2 and 5÷11

). 

2)

 The “

Cartridge

” is not working, please re-

place  with  new  one. 

3)

  If  a  new  “

Cartridge

”  is  installed  or  it  is  not  correctly  connected  or  a  not  compatible  one  is 

mounted. Please check the cartridge connections and compatibility (

see on page 1

) these checks are made switching 

off and on the device. If the condition does not change, it will be necessary to replace the unit and/or send it back 
to the supplier to repair. 

Yellow and green Led activates (

FAULT relay activates and 0 mA output signal

):

 this happens when the “

Cartridge

” is 

not working. First try to perform the procedure of “

ZERO

” as described in the section

 “

Test and Calibration> Zero adjust

” 

then disconnect and connect the unit, finally try to replace a new 

Cartridge

”. If the condition is not change, please 

replace the unit and/or send it back to the supplier to repair. 

All Led activates (

FAULT relay activates and >20 mA output signal

):

 this happens when the “

Cartridge

” is not working or 

gas concentration is higher than F.S. If there are not any gas leaks and the condition is not change, it will be nec-
essary to replace the unit and/or send it back to the supplier to repair. 

INSTALLATION 

The detector must be accurately installed and testing according to the national dispositions in force on the safety of 
the plants and installation of electric devices in areas with danger of explosion. 

Mounting

: The 

Fig. 2

 shows the instrument size. The unit must be positioned vertically with the sensor downwards.  

47RTS282EA 

and

 47RTS282EA-H 

positioning

should be fixed at 30÷50 cm from the ceiling (

NH

3

 gas is lighter than air

). 

47RTS282EC-S 

and

 47RTS282EC-H 

positioning

should be fixed at 1.60m from the floor (

CO 

gas is a little lighter than 

air). 

47RTS282ES 

positioning

should be fixed at 30÷50 cm from the floor (

SO

2

 gas is heavy as air) 

47RTS282EH 

positioning

should be fixed at 30-50 cm from the floor (

H

2

S

 gas is heavier than air). 

47RTS282EHCN 

positioning

should be fixed at 1.60 m from the floor for the protection of persons or over the likely 

point of emission. (

HCN 

gas is a little lighter than air

). 

47RTS282EN 

positioning

should be fixed at 1.60 m from the floor 

(

NO

 gas is heavy as air). 

47RTS282EN2 

positioning

should be fixed at 

30÷50

 cm from the floor 

(

NO

2

 gas is heavier as air). 

47RTS282EHCL 

positioning: should be fixed at 30÷50 cm from the floor 

(

HCL

 gas is heavier than air). 

47RTS282ECL 

positioning: should be fixed at 30÷50 cm from the floor 

(

CL

2

 gas is much heavier than air). 

Electrical Connection (

see Fig.2

)

: the maximum distance to install each detector from the power supply show in the 

Table 1

. If more than one detector is to be powered in parallel, it is necessary to consider the voltage drop across 

the supply cable. Normally use a two wire cable (

not shielded

) for power  the conductors for output relay. 

If 

the output signal is used in mA, please use 3 conductors screened  conductors for relay output. The max 
load resistor is 50 ohm with 12Vdc power supply, while is 400 ohm with 24Vdc power supply (

see Fig.4

). 

Power Supply terminals, on the main board, are plug-in type, it is necessary to extract them to make the connec-
tion, pay attention when you insert them again, being polarized. The relays terminals, on outputs board, are fixed. 
The sealed relays are tension free 

SPST (

S

ingle 

P

ole 

S

ingle 

T

hrow) 

contacts and should be set NO (Normally Open) or 

NC (Normally Closed) by positioning the 4th Dip-Switch (

see Table 2

). With the Dip-Switches from 1 to 3 the concen-

tration for alarm activations is determined. Some alarms can be set with TLV-TWA and STEL functioning. 

Note: Dip-Switch should be set with instrument powered off. Dip-Switch settled in reserved positions acti-

vates FAULT Led indication (see “Operational Description > Faults”). 

Important: 

Once installation is completed, power up the unit, wait about 

30 to 60 minutes

 and then to adjust the 

sensor to the environment, 

only if it is necessary

, carry out the 

Zero Adjust 

(

see 

Test and Calibration

). 

COMPATIBILITY WITH OTHER CENTRAL UNITS: In case of a central unit other than ours, 

please verify the 

max load resistor as shown in 

Fig. 4

The max load resistor is 50 ohm with 12Vdc power supply, while is 400 ohm 

with 24Vdc power supply. 

We suggest using 24Vdc power supply. 

WARNING 

Average life

: In clean air and in normal working condition the 

sensor's life is about 2 years.

 After this period the 

yellow Led “

FAULT

” flashes every 4 seconds, is necessary replacing the “

Cartridge Sensor

”. 

Periodical testing

: we advise to carry out working tests every 6 or 12 months. 

Tests, Zero Adjust and Calibration

 

with sample gas bottle, as explained in the next chapter “

Tests and Calibration

”. 

Note:

  the  detector  is  not  able  to  detect  gas  leaks  occurring  outside  the  room  where  it  is  installed,  neither  inside 

walls or under the floor. 

Sensor operating limits: 

the electrochemical cell, in any case, should not be exposed to temperatures lower than 

-40°C  or  higher  than  60°C.  The  electrochemical  cell  can  be  damaged,  if  it  is  exposed  to  concentrations  over  the 
limit specified in the table, depending on the model. If this condition occurs, please replace the “

Cartridge Sensor

”. 

47RTS282EA 

47RTS282EA-H 

47RTS282EC-S 
47RTS282EC-H 

47RTS282ES  47RTS282EH  47RTS282EHCN  47RTS282EN  47RTS282EN2  47RTS282EHCL  47RTS282ECL 

500ppm NH

3

  1000ppm CO  150ppm SO

2

  500ppm H

2

S  100ppm EHN  1000ppm NO  150ppm NO

2

  >30ppm HCL  >50ppm CL

2

 

Safety: 

electrochemical  Cell  contains  a  small  quantity  of  acid.  It  is  possible  that  either  a  very  strong  mechanical 

action or an incorrect instrument use beyond the limits of its operational functioning could provoke a liquid leak out 
of the sensor. Should this event occurs, please avoid touching the come out liquid. Should a contact with either the 
skin or eyes occur, wash immediately and abundantly with water. 

Cross sensitivity to other gases:

 this detector is designed to detect gas leaks at a very low concentration. The 

electrochemical  cells  employed  have  a  good  resistance  towards  products  such  as  sprays,  detergents,  glues  and 
paints. 

However, in case of products containing substances in great quantity, these could interfere with the Sensor 

Summary of Contents for 47RT282EA

Page 1: ...rio Contents Sommaire Caratteristiche tecniche Technical specifications Caract ristiques techniques 2 IT DESCRIZIONE 4 NOTE SUL GAS RILEVATO DAI VARI MODELLI 4 FUNZIONAMENTO 5 INSTALLAZIONE 6 AVVERTEN...

Page 2: ...ensor limits Limite chelle 500 ppm 500 ppm 1000 ppm 1000 ppm 150 ppm 500 ppm Vita media in aria pulita Average Life in fresh air Vie moyenne en air pur 2 anni years ans 2 anni years ans 3 anni years a...

Page 3: ...th mois 2 mese month mois 2 mese month mois 3 mese month mois 2 mese month mois Risoluzione Resolution R solution 0 1 ppm 1 ppm 1 ppm 0 7 ppm 0 1 ppm Tempo di risposta T90 Response Time T90 Temps de r...

Page 4: ...respirato dalle persone dai polmoni raggiunge il sangue dove impedisce il trasporto dell ossigeno ai tessuti e agli organi 47RTS282EC H identico al precedente ma utilizza un sensore di livello superi...

Page 5: ...impostato Il rel ALARM 2 interviene dopo 30 secondi oppure immediatamente quando superato il livello TLV STEL Il 3 Led rosso ALARM 3 si accende se la concentrazione di gas supera il 3 livello d allarm...

Page 6: ...nati prima d alimentare il rilevatore Se lo si utilizza con i Dip Switch in posizione riservata vietata sar attivata l indicazione di Guasto vedi Funzionamento Guasti Importante terminata l installazi...

Page 7: ...ione del modello in questo caso procedere alla Calibrazione oppure sosti tuire la Cartuccia Se fosse gi acceso solo il 1 Led rosso invece di lampeggiare si spegner per conferma 47RTS282EA 47RTS282EA H...

Page 8: ...a toxic colourless and with a character istic pungent smell lighter than air its density as to air is 0 6 His TWA is 25ppm Time Weighted Average and STEL is 35ppm Short Term Exposure Limit His LEL Low...

Page 9: ...idity variations The cali bration is carried out with specific gas to be detected Anyway it can contemporaneously detect other gases that should be present in the same environment as listed in tables3...

Page 10: ...the conductors for output relay If the output signal is used in mA please use 3 conductors screened cables conductors for relay output The max load resistor is 50 ohm with 12Vdc power supply while is...

Page 11: ...ill remain lighted for around 5 seconds then the detector returns at the conditions of normal operation It is advisable to perform this operation every 12 months according to the use Note this functio...

Page 12: ...C sont d tecteurs ponctuel pour gaz toxiques quip e d un capteur a cellule lectrochimiques Le d tecteurs peut tre utilis en d tecteur ponctuel avec asservissements incorpor s ainsi qu en syst mes cen...

Page 13: ...rtie dans les proc d s de combustion en partie par les missions naturelles des ruptions volcaniques des incendies ou des activit s civiles et industriels de combustion tels que les transports v hicule...

Page 14: ...en panne la remplacer par une nouvelle 3 si une nouvelle Car touche est install e ou bien elle n est pas correctement connect e ou bien elle n est pas compatible Contr ler les connexions avec la Carto...

Page 15: ...de solvants organiques hydro g ne alcool en quantit s lev es des fausses alarmes peuvent appara tre et que le capteur devra pour retrouver ses conditions de fonctionnement normales rester longtemps en...

Page 16: ...et maintenir cette pres sion tant que la 1 re et la 3 me LED rouge ne restent pas teintes durant au moins 2 secondes si en revanche la 1 reLED rouge continue clignoter plus de 5 6 minutes cela signifi...

Page 17: ...0 10 2 Biossido di azoto Nitrogen dioxide dioxyde d azote 20 ppm 2 2 1 16 Cloro Clorine Chlore 1 ppm 0 0 0 Etanolo Ethanol thanol 200 ppm 0 0 2 5 0 Etilene Ethylene thyl ne 100 ppm 0 0 80 50 0 1 Idro...

Page 18: ...armes Relais Ritardo dei Rel in Secondi Relays Delay Seconds retarde du relais Secondes 1 2 3 ALARM 1 ALARM 2 ALARM 3 ALARM 1 ALARM 2 ALARM 3 FAULT OFF OFF OFF 1 5 ppm 2 5 ppm 5 0 ppm 12 30 60 30 ON O...

Page 19: ...vato Reserved R serv Risevato Reserved R serv OFF ON ON Risevato Reserved R serv Risevato Reserved R serv ON ON ON Risevato Reserved R serv Risevato Reserved R serv Tabella 12 Table 12 Tableau 12 47RT...

Page 20: ...a di collegamento Wiring diagram Sch ma TESTmV TP2 TP1 Scheda Uscite Rel Relays Output Board Sortie sur Realis S 12 24V mA 12 24Vdc Alimentazione Power Supply Alimentation Fig 3 Tester di calibrazione...

Reviews: