1. Product introduction
-1-
TC-U9AF-CO/Z
ZigBee Carbon Monoxide Gas Detector Installation Instructions
2.Specification
TC-U9AF-CO/Z is very sensitive to detect the carbon monoxide concentrations. When the gas concentration to achieve a certain
standard. The detector will sound and light alarm. And transmit the alarm signal to the alarm center at the same time. This detector,
with voice broadcast, ZigBee report, temperature mutation alarm, LCD display concentration and other functions, and you can
touch the button to set the alarm concentration.
Its stability, long lifespan, low consumption, wall-mounted installation, elegant in design,360 degree full detection. Easy installation,
safe and reliable. Commonly used in household residential, real estate and villas, hotels, apartments some of existence of combustible
locations.
3.Function Description
1. LCD display concentration: 0PPM is displayed when CO concentration is less than 30PPM.
2. By touching the button to set the CO alarm concentration, alarm temperature and alarm humidity: Open the display, trigger
the button again to the relevant function.
3. Sudden temperature alarm: normal standby, when detecting that room temperature continuously changes more than 3
℃,
it will trigger the detector alarm.
4. Alarm LCD screen after 30s no operation, automatically shut down.
4.Network Settings
1. Adjust the gateway to the access mode.
2. Press the key KEY3 briefly, the detector indicator light will flash, when the network is successful, the indicator light will be on
for 2 seconds;
3. If network can not be normal, long press on the code key for 10 seconds, the indicator light will be on for 2 seconds , then
release the key and press the code key again.
5.Key Function Description
Parameter
Working Voltage
Index
DC6V(3pcsCR2450 battery)
Monitor current:
≤
20uA
Alarm current:
≤
180mA@max
Carbon monoxide( CO)
150ppm(default)
50
℃
(default)
0%RH(default off)
0~999ppm
0~60
℃
30%RH~100%RH
ZigbeeIEEE802.15.4
2.4GHZ
{ 50,75,100,150,200,300}ppm options
{30,35,40,45,50,55,60}
℃
options
{0,40,45,50,55,60,65,70,75,80,85,
90}%RH options
Working Current
Test Gas
Alarm Concentration
Alarm Temperature
Alarm Humidity
Concentration Display Range
Temperature Display Range
Humidity Display Range
Network Protocol
Wireless Emitting Frequency
Working Environment
Remarks
temperature:- 10
℃
~50
℃
humidity:15%-95%RH
(No condensation)
KEY2
KEY1
KEY3
G A S
L E A K A G E
p p m
10
0
60
G A S
L E A K A G E
p p m
10
0
60
%RH
℃
{0(OFF),40,45,50,55,60,
65,70, 75,80,85,90}
Remarks
The code key
Function
Operation Status
Press once or release
for one second
Step 1: Press and hold
for 3 seconds
Step 2: Press and hold
for 3 seconds
Step 3: Press and hold
for 3 seconds
Step 4: Press and hold
for 3 seconds
long press 5 seconds
at the meantime
Manually test alarm
Set the alarm
concentration
Set the alarm
temperature
Set the alarm
humidity
Settings saved
successfully
The system is
about to reset
ZigBee only
Parameter settings
{50,75,100,150,
200,300}
{ 30,35,40,45,
50,55,60}
KEY3(Key on the left
side of the hole)
Voice prompt "It is about to
proceed alarm test, do not panic"
You must have this action to
save the settings.
Key
KEY1(Down key)
KEY1+KEY2
Increase: Release KEY1 once
Reduce: Release KEY2 once
Enroll/Delete
Note:
①
Under standby mode, long press KEY1 or KEY2 and light display;
②
After entering the menu, no operation for 15 seconds, which will exit the menu setting.